–165–
HARVEST CYCLE HEADMASTER CONTROL
VALVE FAILURE LIST
CVD675/CVD0875/CVD1075/CVD1475/CVD1476/
CVD1875/CVD2075
Temperature of the compressor discharge line and
liquid line to the ice machine receiver feel the
same for the first 30 seconds of the harvest cycle.
The headmaster is functioning correctly.
The compressor discharge line is noticeably
warmer than the liquid line to the ice machine
receiver.
Headmaster valve is not bypassing 100%. Replace
headmaster valve.
Ref
rige
ran
t Fl
ow
No
Flo
w
Step 3 Details
Grasp Here with Hands to Compare Temperatures
LIQUID LINE
FROM CONDENSER
Summary of Contents for CVD0675
Page 2: ......
Page 75: ... 69 QDUAL DISTRIBUTION TUBE SV1780 EVAPORATOR WATER PUMP WATER CURTAIN WATER TROUGH ...
Page 153: ... 149 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 203: ......