–182–
Q1400C/CVD1476 REMOTE WATER COOLED
NOTE:
These characteristics may vary depending on
operating conditions.
CYCLE TIMES
24-HOUR ICE PRODUCTION
OPERATING PRESSURES
CONDENSER WATER CONSUMPTION
Freeze Time + Harvest Time = Cycle Time
Air Temp.
Entering
Condenser
°F/°C
Freeze Time
Harvest
Time
Water Temperature °F/°C
50/10.0
70/21.1
90/32.2
35 to 70/
1.6 to 21.1
10.7-12.7
12.4-14.7
14.6-17.3
.75-2.5
80/26.7
10.8-12.9
12.5-14.9
14.7-17.4
90/32.2
10.9-13.0
12.6-15.0
14.8-17.5
100/37.8
10.9-13.0
12.7-15.0
14.9-17.6
1
Times in minutes.
Air Temp.
Entering
Condenser
°F/°C
Water Temperature °F/°C
50/10.0
70/21.1
90/32.2
35 to 70/
1.6 to 21.1
1420
1245
1070
80/26.7
1400
1230
1065
90/32.2
1395
1225
1060
100/37.8
1390
1220
1055
1
Based on average ice weight of one Harvest cycle 12.00-14.00 lb.
(6.00-7.00 lb. per evaporator).
Air Temp.
Entering
Condenser
°F/°C
Freeze Cycle
Harvest Cycle
Discharge
Pressure
psig
Suction
Pressure
psig
Discharge
Pressure
psig
Suction
Pressure
psig
35 to 70/
1.6 to 21.0
265-235
48-28
150-170
70-90
80/26.7
265-235
48-28
150-170
70-90
90/32.2
265-235
48-28
150-170
70-90
100/37.8
270-235
49-29
160-180
70-90
110/43.3
275-235
50-30
160-180
75-95
Refer to page 176.
Condenser
Water
Consumption
90/32.2 Air Temperature Around Ice Machine
Water Temp.
°
F/
°
C
50/10.0
70/21.1
90/32.2
Gal/24 Hours
1200
2100
4000