Part Number 000015432 Rev02 5/21
29
Remedial Cleaning Procedure
Ice machine cleaner/descaler is used to remove lime scale
or other mineral deposits. It is not used to remove algae or
slime. Refer to “Sanitizing Procedure” for removal of algae
and slime. To initiate a descaling cycle using Manitowoc’s
Cleaning Technology use the following procedure.
Step 1
To start a cycle, move the toggle switch to the
CLEAN position. Water will flow through the water dump
valve and down the drain.
Step 2
Remove the top panel and translucent plastic
ice chute cover. Wait about one minute then add the
proper amount of Manitowoc Ice Machine Cleaner/
Descaler. Rinse the descaler from the top of the evaporator
with 2 ounces (60 ml) of clear water and re-install cover
,
Caution
Use only Manitowoc approved Ice Machine Cleaner/
Descaler part number 000000084. It is a violation
of Federal law to use these solutions in a manner
inconsistent with their labeling. Read and understand
all labels printed on bottles before use.
Model
Amount of Cleaner/Descaler
Part Number 000000084
CNF0201 CNF0202
2 ounces (60 ml)
Summary of Contents for CNF0201
Page 2: ......
Page 20: ...20 Part Number 000015432 Rev02 5 21 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 40: ...40 Part Number 000015432 Rev02 5 21 Remove Screws ...
Page 43: ...Part Number 000015432 Rev02 5 21 43 9 Lift out ice damper ...
Page 44: ...44 Part Number 000015432 Rev02 5 21 10 Lift out ice strainer ramp ...
Page 45: ...Part Number 000015432 Rev02 5 21 45 11 Turn ice wiper counterclockwise to remove ...
Page 54: ...54 Part Number 000015432 Rev02 5 21 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 104: ...104 Part Number 000015432 Rev02 5 21 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 110: ...110 Part Number 000015432 Rev02 5 21 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 119: ......