Detailed Descaling/Sanitizing Procedure
This procedure must be performed a minimum of once
every six months:
• All ice must be removed from the bin/dispenser.
• The ice machine and bin/dispenser must be
disassembled, descaled and sanitized.
• The ice machine produces ice with the descaler and
sanitizer solutions.
• All ice produced during the descaling and sanitizing
procedure must be discarded.
Remedial Cleaning Procedure
Perform this procedure as often as required for your water
conditions:
• Allows descaling the ice machine without removing all
of the ice from the bin/dispenser.
• Removes mineral deposits from areas that are in direct
contact with water during the Freeze cycle (reservoir,
evaporator, auger, drain lines).