Part Number 000015432 Rev02 5/21
107
Cycle Times/24-Hour Ice Production/
Refrigerant Pressure Charts
These charts are used as guidelines to verify correct ice
machine operation.
Accurate collection of data is essential to obtain the
correct diagnosis.
• Refer to “Refrigeration System Diagnostics” for the
data that must be collected. This list includes: before
beginning service, ice production check, installation/
visual inspection, water system checklist, safeguards,
discharge and suction pressure analysis.
• Ice production checks that are within 10% of the chart
are considered normal. This is due to variances in
water and air temperature. Actual temperatures will
seldom match the chart exactly.
• Zero out manifold gauge set before obtaining pressure
readings to avoid misdiagnosis.
• Discharge and suction pressure are highest at the
beginning of the cycle. Allow system to stabilize, then
verify the pressures are within the range indicated.
• Water temperature will affect suction and discharge
pressure - 50° water temperature will result in
pressures on the lower end of the ranges specified.
90° water temperatures will result in pressures on the
upper end of the ranges specified.
Charts
Summary of Contents for CNF0201
Page 2: ......
Page 20: ...20 Part Number 000015432 Rev02 5 21 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 40: ...40 Part Number 000015432 Rev02 5 21 Remove Screws ...
Page 43: ...Part Number 000015432 Rev02 5 21 43 9 Lift out ice damper ...
Page 44: ...44 Part Number 000015432 Rev02 5 21 10 Lift out ice strainer ramp ...
Page 45: ...Part Number 000015432 Rev02 5 21 45 11 Turn ice wiper counterclockwise to remove ...
Page 54: ...54 Part Number 000015432 Rev02 5 21 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 104: ...104 Part Number 000015432 Rev02 5 21 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 110: ...110 Part Number 000015432 Rev02 5 21 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 119: ......