Part Number 000015432 Rev02 5/21
59
NO ICE PRODUCTION
The ice damper did not open and close at least once every
90 seconds in the freeze cycle.
Operation
During the first 12 minutes of operation:
The control board must see the ice damper open/close at
least once. This allows time for ice production to start at all
ambient temperatures.
After the initial 12-minute period:
The control board must see the ice damper open/close at
least once every 90 seconds.
When the ice damper does not open/close within the
specified time, the control board will:
1. De-energize the compressor and gear motor.
2. HES #1 light on the control board will flash (the light
will not flash if the ice damper is open).
3. A 15-minute delay is initiated.
4. After the 15-minute delay the ice machine will:
A. Energize the dump valve for 30 seconds
B. Energize the gear motor
C. Wait until the water float valve closes and then
energize the compressor and fan motor.
Summary of Contents for CNF0201
Page 2: ......
Page 20: ...20 Part Number 000015432 Rev02 5 21 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 40: ...40 Part Number 000015432 Rev02 5 21 Remove Screws ...
Page 43: ...Part Number 000015432 Rev02 5 21 43 9 Lift out ice damper ...
Page 44: ...44 Part Number 000015432 Rev02 5 21 10 Lift out ice strainer ramp ...
Page 45: ...Part Number 000015432 Rev02 5 21 45 11 Turn ice wiper counterclockwise to remove ...
Page 54: ...54 Part Number 000015432 Rev02 5 21 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 104: ...104 Part Number 000015432 Rev02 5 21 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 110: ...110 Part Number 000015432 Rev02 5 21 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 119: ......