MAN B&W
6.04
Page 6 of 12
MAN Diesel
198 71 44-6.2
MAN B&W 50 Mark 8/7/6, 46-26 Mark 9/8/7/6 engines
Jacket Cooling Water Temperature Control
When using a normal freshwater generator of the
singleeffect vacuum evaporator type, the fresh-
water production - based on the available jacket
cooling water heat Qjw - may, for guidance, be
estimated as 0.03 t/24h per 1 kW heat, i.e.:
M
fw
= 0.03 x Qjw t/24h 15%/0%
[3]
where
M
fw
is the freshwater production in tons per 24
hours
and
Q
jw
is to be stated in kW
If necessary, all the actually available jacket cool-
ing water heat may be used provided that a spe-
cial temperature control system ensures that the
Valve A: ensures that T
jw
< 80° C
Valve B: ensures that T
jw
> 80 – 5° C = 75° C
Valve B and the corresponding bypass may be omitted if, for example, the freshwater generator is equipped with an automatic
start/stop function for too low jacket cooling water temperature
If necessary, all the actually available jacket cooling water heat may be utilised provided that a special temperature control system
ensures that the jacket cooling water temperature at the outlet from the engine does not fall below a certain level
178 23 700.0
Jacket cooling water system
Freshwater generator system
Expansion tank
Jacket cooling
water circuit
min
Tjw
max
Tjw
L
M
K
Seawater
In Out
Condensator
Produced
freshwater
Evaporator
Brine out
B
Jacket water
cooler
Cooling
water
Deaerating tank
Jacket water pumps
Main engine
A
jacket cooling water temperature at the outlet from
the engine does not fall below a certain level. Such
a temperature control system may consist, e.g.,
of a special bypass pipe installed in the jacket
cooling water system, see Fig. 6.04.05, or a spe-
cial builtin temperature control in the freshwater
generator, e.g., an automatic start/stop function, or
similar.
If such a special temperature control is not ap-
plied, we recommend limiting the heat utilised to
maximum 50% of the heat actually available at
specified MCR, and only using the freshwater gen-
erator at engine loads above 50%. Considering the
cooler margin of 10% and the minus tolerance of
15%, this heat corresponds to 50 x(1.000.15)x0.9
= 38% of the jacket water cooler capacity Q
jw,M
used for dimensioning of the jacket water cooler.
Fig. 6.04.05: Freshwater generators. Jacket cooling water heat recovery flow diagram
Summary of Contents for B&W S50ME-B9.3-TII
Page 4: ......
Page 10: ......
Page 11: ...MAN B W MAN Diesel Engine Design 1 ...
Page 12: ......
Page 27: ...MAN B W MAN Diesel Engine Layout and Load Diagrams SFOC 2 ...
Page 28: ......
Page 53: ...MAN B W MAN Diesel Turbocharger Selection Exhaust Gas By pass 3 ...
Page 54: ......
Page 58: ......
Page 59: ...MAN B W MAN Diesel Electricity Production 4 ...
Page 60: ......
Page 92: ......
Page 93: ...MAN B W MAN Diesel Installation Aspects 5 ...
Page 94: ......
Page 124: ......
Page 133: ...MAN B W MAN Diesel List of Capacities Pumps Coolers Exhaust Gas 6 ...
Page 134: ......
Page 154: ......
Page 155: ...MAN B W MAN Diesel Fuel 7 ...
Page 156: ......
Page 170: ......
Page 171: ...MAN B W MAN Diesel Lubricating Oil 8 ...
Page 172: ......
Page 188: ......
Page 189: ...MAN B W MAN Diesel Cylinder Lubrication 9 ...
Page 190: ......
Page 199: ...MAN B W MAN Diesel Piston Rod Stuffing Box Drain Oil 10 ...
Page 200: ......
Page 202: ......
Page 203: ...MAN B W MAN Diesel Central Cooling Water System 11 ...
Page 204: ......
Page 209: ...MAN B W MAN Diesel Seawater Cooling System 12 ...
Page 210: ......
Page 220: ......
Page 221: ...MAN B W MAN Diesel Starting and Control Air 13 ...
Page 222: ......
Page 227: ...MAN B W MAN Diesel Scavenge Air 14 ...
Page 228: ......
Page 239: ...MAN B W MAN Diesel Exhaust Gas 15 ...
Page 240: ......
Page 254: ......
Page 255: ...MAN B W MAN Diesel Engine Control System 16 ...
Page 256: ......
Page 265: ...MAN B W MAN Diesel Vibration Aspects 17 ...
Page 266: ......
Page 280: ......
Page 281: ...MAN B W MAN Diesel Monitoring Systems and Instrumentation 18 ...
Page 282: ......
Page 302: ......
Page 306: ......
Page 307: ...MAN B W MAN Diesel Dispatch Pattern Testing Spares and Tools 19 ...
Page 308: ......
Page 322: ......
Page 323: ...MAN B W MAN Diesel Project Support and Documentation 20 ...
Page 324: ......
Page 332: ......
Page 333: ...MAN B W MAN Diesel Appendix A ...
Page 334: ......