B) FIRST OPERATING
Maktek Autorized Services must do the first operating to validate the guarantee
conditions. These steps must be applied:
Be sure that fuse switch which makes energy connection of boiler, is open. If the
boiler has waited for a long time after the installation in OFF mode without fist
operating,Autorized service must check the circulation pump in case of squeezing.
• Turn on all the valves on boiler and installation pipes.
• Closed circuit water pressure must ne 1,5 bar (page 13)
• Choose the position of use with the help of P1 and P2 buttons on control panel
(page 7 and 15).
• You can start using the boiler by making intended temperature settings at chosen
position.
CIRCULATION PUMP PRESSURE CURVE
MAKTEK Boiler Circulation pump is 3 speed. Making circulation setting is possible
according to resistance required by installation.
23-29 kW
40kW
Water Flow m3/h)
Height (m)
13