8. CLEANING AND MAINTENANCE INSTRUCTIONS
•
In order to use your boiler safely for a long period of time, please pay
attention to below mentioned rules of cleaning and maintainence.
•
Pellets of 6-8mm in diameter, 6-30mm in length, made of wood with
shells peeled, moisture content 10% -15%, 3500-4000kcal lower heat
value, no chemicals and additives were added and in suitable
standarts should be used in the boiler.
•
Pellets made of chipboard and MDF powder should never be used in
the boiler.
The ash drawer of the boiler should be cleaned when it is full.
•
In order to obtain high efficiency from your boiler, you must use high
quality, high calorie and dry fuel.
•
To clean the smoke pipe,clean the helezones by shaking them by
moving the cleaning
handle
on the left side of the boiler about 10
times
up and down once a day. In this way, it is prevented that
the
smoke pipes are blocked with combustion wastes.
•
The air
flows
in the combustion chamber and the combustion
chamber
is
automatically cleaned with the fan. If any deterioration
is
observe
d
in the combustion, combustion chamber can be cleaned by
inserting a hard material with appropriate diameter in its holes.
•
Cut
off
all
electricity connections before
starting
maintenance of the
boiler.
Ventilate the air in tha place while cleaning the boiler.
Before the winter season, maintain the electrical, chimney and
plumbing connections of the boiler.
Check boiler water pressure
regularly.
(Ideal working pressure 1.5bar
)
We recommend that you take your periodic maintenance to our authorized services.
9.SUGGESTIONS FOR ECONOMIC USE
•
For proper ventilation, windows should be completely opened for a short
time and radiator valves should be turned off at the same time.
•
Pay attention not to heat up the place too much: room temprature must
be kept at 20
°C
.
Keeping room temperature 1
°C
less makes a
6%
economy on heating costs.
•
When the weather gets dark, close the shutters if any.
•
Do not cover the fronts of the radiators with
furniture
.
•
Take advantage of the boiler control panel's special setting possibilities,
and set the desired
DHW
temperature from the operating panel. In this
case, you will avoid to overheat the water and unnecessary fuel
consumption.