19
7.2 WARNINGS ABOUT PELLET
Pellets of 6-8
mm in diameter, 6-30
mm in length, made of wood with
shells peeled, moisture content 10% -15%, 3500-4000kcal lower heat
value, no chemicals and additives were added and in suitable standarts
should be used in the boiler.
Our company is not responsible for any faults
and inefficient operation in case of using an improper pellet.
It is important
to make sure that there are no foreign substances in the pellet.
Damage
caused by foreign material coming out of the pellet is not covered by the
warranty.
Pellets made of chipboard and MDF powder should never be used in the
boiler.
7.3 USAGE PRECAUTIONS
When the boiler water temperature reaches 30°C in burning, the circulation
pump is activated. This prevents both unnecessary electricity consumption
and prevents the boiler from the water vapor damage caused from heating
up quickly to sweat. At the same time, it prevents sending not fully heated
water to the radiators.
The boiler water temperature continuously decreases when the
fuel is exhausted and the circulation pump is deactivated when it
reaches 30°C. When the boiler water temperature drops to 25°C, all
functions stop.
The fan is automatically switched off when the boiler water temperature
reaches at the set thermostat limit. The fan starts to work again when the
boiler water temperature falls below 5°C from the set temperature.
You can
monitor the
activation and deactivation of
the circulation pump,
fan and reductor from symbols on LCD sceen in control panel.
As long as the boiler is not unplugged, the circulation pump will
automatically switch on for 3 seconds in 25 hours. This prevents faults
that may occur in the pump in case of disuse for a long period of time.
ATTENTION!!!
In case of power cut, the boiler water may increase
to boiling point temperature because it is difficult to control
the high heat in the b
oiler
due to the circulation pump stop.
For this reason,
1-
Never open the boiler doors.
2-
If there are bypass valves in the system, open them.
3-
When power is supplied, make all settings to the old operating situation
.