Page
36
of
36
PRO3 – WASHING A MILKING DEVICE
diode no.
1
2
3
4
5
6
7
8
H
comments
relay no.
1
2
3
4
5
6
7
8
mode step
time CW ZW PP PML ZZ ZD1 ZD2 G H di
O
C Hi
war
m
ing
1
15:00
1
1
1
max. time
2
03:00
1
1
1
3
00:30
1
1
1
ri
ns
ing
4
15:00
1
1
max. time
5
05:00
1
1
6
00:30
1
1
1
wash
ing
7
15:00
1
1
1
max. time
8
30:00
1
1 70 max. time
9
00:20
1
1
10
08:00
1
1
11
04:00
1
1
1
12
00:30
1
1
1
1
ri
ns
ing
13
15:00
1
1
max. time
14
05:00
1
1
15
00:30
1
1
1
total time 27:20
total time does not take into account the time of pouring water – with the hydrostatic switched
on, it is not necessary to know the time needed to pour water.
PRO4 – WASHING A MILK TANK
diode no.
1
2
3
4
5
6
7
8 H
comments
relay no.
1
2
3
4
5
6
7
8
mode step
time CW ZW PPR PM ZZ ZD1 ZD2 G H di
O
C Hi
ri
ns
ing
1
02:30
1
2
01:00
1
1
1
3
01:00
1
1
4
02:30
1
1
wash
ing
5
02:30
1
1
6
30:00
1
1 50
max. time
warm water heating up
7
00:20
1
1
1
8
01:00
1
1
1
1
9
06:30
1
1
1
1 50 2
thermostatic work
10
03:00
1
ri
ns
ing
11
02:30
1
12
01:00
1
1
1
13
01:00
1
1
14
04:00
1
total time 28:50