scaling the temperature sensor
5
CU
every 0,2
O
C
wartość
skalowalna
UU
function not available to the installer
/ user
3
delay time of switching on the
chiller and the stirrer after
connecting the controller to the
mains or power supply decay
dE
setting the time from 1 s. to 999 s.,
every 1 s.
5 (s.)
display status with control disabled
d1
0 – the dot is displayed
1 – current measured temperature
is displayed
0
return to the factory settings
FA
0 – inactive
1 – active; after setting to 1 and
disconnecting the controller from
the power supply, switching it back
on restores the factory settings and
the function value is reset to 0
0
exit from the setting mode
EE
1
Adjustments must be made so that the condition b1<b2 is always met. The values of parameters b1 and b2
are not control temperature settings; these are the temperature values between which the control temperature
can be set (a section from the entire control temperature range of the controller).
2
This function is active only when the minimum standstill time of the chiller has been set (CF).
3
Changing the parameter value is not recommended, because it can lead to incorrect operation of the
controller, and even its damage.
4
The manual stirrer operation, depending on the washing program set, can be associated with the washing
segment.
5
Set up during the production phase – do not change without a clear need.