57
Majestic • JADE32IN, JADE42IN, JADE42IL Installation Manual • 2491-986 Rev. K
• 10/18
D. Decorative Front Finishing
WARNING! Risk of Fire!
A decorative front is required
for this model. DO NOT operate this appliance without a
decorative front in place.
Only decorative fronts certified for use with this appliance
model may be used. Contact your dealer for a list of deco
-
rative fronts that may be used.
FRONT FACE OF FIREPLACE
DECORATIVE FRONT
1 IN. MAX.
FINISHING MATERIAL
(TOP EDGE)
Figure 10.7 Overlap Fit Decorative Front
(CFT and PFF Decorative Fronts)
Finishing materials 1 inch maximum thick.
Stop finishing material flush with opening.
Overlap Fit - CFT and PFF Decorative Fronts
(0 Inches to 1 Inch Thick Finishing Material)
Figure 10.8 Overlap Fit Method
(CFT and PFF Decorative Fronts)
FACTORY-INSTALLED
NON-COMBUSTIBLE BOARD
NON-COMBUSTIBLE
FINISHING MATERIAL
0 - 1 IN. THICK
NON-COMBUSTIBLE
FINISHING MATERIAL
0 - 1 IN. THICK
CFT
DECORATIVE
FRONT SHOWN
DRYWALL OR
EQUIVALENT (1/2 IN.)
The CFT and PFF decorative fronts are designed to over
-
lap finish materials 0 inches to 1 inch thick. See Figure
10.7 and Figure 10.8.
NOTICE:
This one inch maximum not only includes the
decorative finish materials (marble, tile, slate, etc) but
also the mortar or adhesive used to attach the decorative
finish material
.
The non-combustible finish material can be installed up to
the fireplace opening.