Majestic • JADE32IN, JADE42IN, JADE42IL Installation Manual • 2491-986 Rev. K
• 10/18
44
A. General Information
WARNING! Risk of Shock or Explosion! DO NOT
wire
110-120 VAC to the valve or to the appliance wall switch.
Incorrect wiring will damage controls.
NOTICE:
This appliance must be electrically wired
and grounded in accordance with local codes or, in the
absence of local codes, with
National Electric Code
ANSI/NFPA 70-latest edition
or the
Canadian Electric
Code CSA C22.1.
• Wire the appliance junction box to unswitched 110-
120 VAC. This is required for proper operation of the
appliance.
• A 110-120 VAC circuit for this product must be protected
with ground-fault circuit-interrupter protection, in
compliance with the applicable electrical codes, when
it is installed in locations such as in bathrooms or near
sinks.
• Low voltage and 110-120 VAC voltage cannot be shared
within the same wall box.
• In some instances, the spark ignition of the fireplace may
cause intermittent, non-damaging, interference during
the lighting sequence with a TV plugged into the same
circuit. It is recommended that the fireplace and TV use
different circuits to mitigate the interference potential. If
interference is occurring on the same circuit, the use of
surge protectors may help alleviate the interference.
8
Electrical Information
WHT
WHT
BLK
BLK
GRN wire
inside box
Copper
ground attached
to GRN screw with
GRN wire
14/2WG
Cover Plate
outside firebox
Romex
Connector
Figure 8.2 Junction Box Detail - JADE42IN/JADE42IL
Junction Box Installation
If the box is being wired from the INSIDE of the appliance:
JADE42IN/JADE42IL:
The junction box is secured to a
bracket. Remove one screw. See Figure 8.2.
JADE32IN:
The junction box is secured to the fireplace
outer wrap. Remove one screw. See Figure 8.3.
• Pull the electrical wires from outside the appliance through
the opening into the valve compartment and secure wires
with a Romex connector. See Figure 8.4.
• Make all necessary wire connections to the junction
box/receptacle and reattach the junction box/receptacle
to the outer shell (JADE32IN) or bracket (JADE42IN/
JADE42IL).
Figure 8.3 Junction Box Detail - JADE32IN
REMOVE ONE SCREW
REMOVE ONE SCREW
Figure 8.4 Junction Box Wiring (Generic Model Shown)
NOTICE: DO NOT
wire
110-120 VAC to wall switch.
BRACKET
FIREBOX LEG
Valve/Control Access
The valve/control cavity is accessible by removing two
screws located in the lower right and left corners of the
fireplace opening. See Figure 8.1.
Once finishing material has been installed, access to the
valve/control cavity is limited to access through the fire
-
box, see Section 9.B.
BOTTOM PANEL SCREW LOCATIONS
LOWER
ACCESS P
ANEL
NOTE: Appliance shown
without glass installed.
Figure 8.1 Remove Lower Access Panel