10002789/0 -3- 

DBT33/DBT36/DBT39

This gas fireplace should be installed by a qualified installer 
in accordance with local building codes and with current CAN 
/CGA-B149 (. 1 or .2) Installation codes for Gas Burning 
Fireplaces and Equipment. 
FOR U.S.A Installations follow local codes and/or the current 
National Fuel Gas Code. ANSI Z223.1.
FOR SAFE INSTALLATION AND OPERATION PLEASE 
NOTE THE FOLLOWING:
1.  This fireplace gives off high temperatures and should be 

located out of high traffic areas and away from furniture 
and draperies.

2.  Children and adults should be alerted to the hazards of the 

high surface temperatures of this fireplace and should stay 
away to avoid burns or ignition of clothing.

3. 

Caution, due to high glass surface temperature children 
should be carefully supervised when they are in the same 
room as the fireplace.

4.  Under no circumstances should this fireplace be modified. 

Parts removed for servicing should be replaced prior to 
operating the fireplace again.

5.  Installation and any repairs to this fireplace should be 

carried out by a qualified service person. A professional 
service person should be contacted to inspect this fireplace 
annually. Make it a practice to have all of your gas fire-
places checked annually.  More frequent cleaning may 
be required due to excess lint and dust from carpeting, 
bedding material, etc.

6.  Control compartments, burners and air passages in this 

fireplace should be kept clean and free of dust and lint. 
Make sure that the gas valve and pilot light are turned off 
before you attempt to clean this fireplace.

7.  The venting system (chimney) of this fireplace should be 

checked at least once a year and if needed your venting 
system should be cleaned.

8.  Keep the area around your fireplace clear of combustible 

materials, gasoline and other flammable vapour and liq-
uids. This fireplace should not be used as a drying rack for 
clothing, nor should Christmas stockings or decorations 
be hung on or around the fireplace.

9.  Under no circumstances should any solid fuels (wood, 

coal, paper or cardboard etc.) be used in this fireplace.

10.  The flow of combustion and ventilation air must not be 

obstructed in any way.

11.  When the fireplace is installed directly on carpeting, vinyl 

tile or any combustible material other than wood, the 
fireplace must be installed on a metal or wood panel 
extending the full width and depth of the fireplace.

12.  This fireplace must not be connected to a chimney flue 

serving a separate solid fuel burning fireplace.

13.  When the fireplace is not in use it is recommended that the 

gas control valve be left in the 

OFF

 position.

This appliance has been approved for 

after-market mobile home installations

IMPORTANT:

PLEASE REVIEW THE FOLLOWING CAREFULLY

Remove any plastic from trim parts before turning the fire-
place ON.
It is normal for fireplaces fabricated of steel to give off 
some expansion and/or contraction noises during the start 
up or cool down cycle. Similar noises are found with your 
furnace heat exchanger or car engine.
It is not unusual for your gas fireplace to give off some 
odour the first time it is burned.  This is due to the curing 
of the paint and any undetected oil from the manufacturing 
process.
Please ensure that your room is well ventilated - open all 
windows.
It is recommended that you burn your fireplace for a least 
six (6) hours the first time you use it.  If the optional fan 
kit has been installed, place the fan switch in the “OFF” 
position during this time.

I

NSTALLATION

 & O

PERATING

 I

NSTRUCTIONS

L

OCATING

 Y

OUR

 F

IREPLACE

A - Flat on the wall 

B - Cross Corner

C - * Island 

D - ** Room Divider

E - ** Flat on wall (in corner) 

F - Chase Installation

Island (C) and Room Divider (D) installation is possible 
as long as the horizontal portion of the vent system (X) 
does not exceed 20' (6.1 m).  See details in the venting 
section  of this manual.

**  When you install your fireplace in a Room divider (D) 

or flat on the wall in a corner (E), a minimum distance 
of 6" (153 mm) clearance must be maintained from the 
perpendicular wall and the front of the appliance.  See 
(Y) in Fig. 1.

Fig. 1

Summary of Contents for DBT33

Page 1: ...y electric switch Do not use any phone in your building Immediately call yourgas supplier from your neighbours phone Follow the gas suppliers instructions If you cannot reach your gas supplier call th...

Page 2: ...tion Instructions General Venting Information Terminal Location 9 Connecting Direct Vent Components 11 How To Use The Vent Graph 11 Vertical sidewall Applications 12 Vertical sidewall Installations 13...

Page 3: ...or decorations be hung on or around the replace 9 Under no circumstances should any solid fuels wood coal paper or cardboard etc be used in this replace 10 The ow of combustion and ventilation air mu...

Page 4: ...56 mm 14 406 mm 16 406 mm 16 G 810 mm 31 89 946 mm 37 25 946 mm 37 25 H 152 mm 6 181 mm 7 13 190 mm 7 5 I 149 mm 5 87 171 mm 6 75 159 mm 6 25 J 200 mm 7 87 254 mm 10 213 mm 8 38 K 297 mm 11 343 mm 13...

Page 5: ...rojects out 12 305 mm or more from the front of the replace Cold climate Installation Recommendation When installing this unit against a non insu lated exterior wall or chase it is mandatory that the...

Page 6: ...S SPECIFICATIONS Max Min Input Input Model Fuel Gas Control BTU h BTU h DBT33RN Nat Millivolt 15 000 10 500 DBT33RP Prop Millivolt 15 000 11 250 DBT36RN Nat Millivolt 18 000 12 600 DBT36RP Prop Milliv...

Page 7: ...necessary to provide a 1 8 test point up stream of the control When using copper or ex connectors use only approved t tings Always provide a union when using black iron pipe so that the gas line can...

Page 8: ...alignment Take care not to damage the thermocouple thermopile or igniter 9 SIT 820 NOVA Gas Control Valve Fig 9 a Using a Torx T20 or slotted screwdriver remove and save the three pressure regulator m...

Page 9: ...air supply inlet 72 inches 1828mm minimum L clearance above paved side walk or a paved driveway located on public property 84 inches 2133mm mini mum M clearance under veranda porch deck 12 inches 305...

Page 10: ...DBT33 DBT36 DBT39 10 10002789 0 Fig 11 Fig 12 Fig 13 Fig 14 Fig 15...

Page 11: ...s with three sheet metal screws Fig 16 Wipe off excess sealant CANADIAN INSTALLATIONS The venting system must be installed in accordance with the current CAN CGA B149 1 or 2 installation code U S A IN...

Page 12: ...m number of 90 elbows per side wall instal lation is three 3 If a 90 elbow is tted directly onto the replace ange the maximum horizontal vent run before the termination is 36 914 mm If a 90 elbow is u...

Page 13: ...restop with 8 sheet metal screws supplied Install restop assembly Fig 23 Zero clearance sleeve is only required for combustible walls STEP 3 Place replace into position Fig 24 Measure the vertical hei...

Page 14: ...positioned BELOW GRADE INSTALLATIONS When it is not possible to meet the required vent terminal clearances of 12 305mm above grade level a snorkel vent kit is recommended It allows installation depth...

Page 15: ...H THE ROOF APPLICATIONS This Gas Fireplace has been approved for Vertical installations up to 40 12 m in height Up to a 10 horizontal vent run can be installed within the vent system using a maximum o...

Page 16: ...e MUST BE FITTED TO THE APPLIANCE at installation Fitting The Restrictor Plate 1 Remove the window glass frame assembly 2 Locate the rebox baf e assembly in the top rear area of the rebox Fig 32 3 Rem...

Page 17: ...ion and secure Fig 35 7 Install roof support Fig 36 and roof ashing making sure upper ange of ashing is below the shingles Fig 37 8 Install appropriate pipe sections until the venting is above the ash...

Page 18: ...ation Offsets 90 transition elbow kit 7DVRT90 for Vertical Sidewall Applications or thru the roof Telescopic vent sections 7DVP610 6 to 10 adjustable length 7DVP1018 10 to 18 adjustable length 7DVP183...

Page 19: ...llation 45 elbow kit 7TDV45 for Vertical Installation Offsets 90 transition elbow kit 7TDV90 for Vertical Sidewall Applications or thru the roof Telescopic vent sections 7TDVP1218 12 to 18 adjustable...

Page 20: ...th lemon oil Do not use water or household cleaners on any brass components LOUVRE REMOVAL The top louvre panel is removed by lifting the panel vertically and pulling it away from the appliance Fig 39...

Page 21: ...he right support bracket located over the burner housing and place the log in position 6 Place the left top log in position by aligning the hole on the underside of the log with the lug on the top fac...

Page 22: ...ar the centre of the gas control valve Fig 44 45 FLAME CHARACTERISTICS It is important to periodically perform a visual check of the pilot and burner ames Compare them to the pictorials illus trated b...

Page 23: ...gas go to the next step 7 Remove glass door before lighting pilot See Glass Frame Removal in manual 8 Visibly locate pilot by the main burner 9 Turn knob on gas control counter clockwise to PILOT nei...

Page 24: ...DBT33 DBT36 DBT39 24 10002789 0 TROUBLE SHOOTING THE GAS CONTROL SYSTEM HONEYWELL MILLIVOLT VALVE...

Page 25: ...pplied must be used to conduct this test 3 Pilot burning no gas to A Wall switch or wires defective Check wall switch and wires for proper connections main burner Jumper wire across terminals at wall...

Page 26: ...Pilot assembly SIT Top convertible RP 10002265 N A N A 5 Pilot SIT N A 10001295 10001295 6 Pilot SIT Top convertible 10002266 N A N A Pilot ori ce SIT Nat N A 54273 54273 Pilot ori ce SIT Prop N A 542...

Page 27: ...0002822 10001781 10002821 Gasket window glass 57317 57317 57317 19 Clamp window frame assembly 54174 54174 54174 20 Window trim polished brass with magnets 55005 57480 57483 21 Top louvre assembly 100...

Page 28: ...DBT33 DBT36 DBT39 28 10002789 0 PARTS PICTORIAL...

Page 29: ...he white wire of the power line to the chrome screw of the socket assembly 8 Connect the black wire of the power supply line to the brass screw polarized of the socket assembly 9 Re t the socket assem...

Page 30: ...trol will require suitable extension of the component wiring 4 The power supply may be connected in 2 ways Method A Route the 6 lead tted to the unit to a conveniently located wall socket Method B The...

Page 31: ...efractory panels into place to hold the rear panel secure Adjust the top adjustable tabs to hold the side panel against the rebox wall and secure the tab Repeat the procedure on the other side 8 Repla...

Page 32: ...ssemble the Bay Window Kit according to the instruc tions supplied with the kit 5 Place the 2 pieces of ceramic refractory along the base of the bay window Fig 59 6 Hang the Bay Window Assembly over t...

Page 33: ...10002789 0 33 DBT33 DBT36 DBT39...

Page 34: ...VEAU FOYER AU GAZ AJESTIC NC CONTRE TOUS D FAUTS DE FABRICATION ET DE MATI RES PREMI RES POUR UNE P RIODE DgUN AN COMPTER DE LA DATE DgINSTALLATION SUJET AUX CONDITIONS ET LIMITATIONS SUIVANTES 2 4 6...