Majestic DBT33 Installation Instructions & Homeowner'S Manual Download Page 26

DBT33/DBT36/DBT39 -26- 

10002789/0

R

EPLACEMENT

 P

ARTS

 L

IST

Items marked ‘*’ are not shown in the following parts pictorial page.

 Ref. Description 

DBT33 

DBT36 

DBT39 

 1 Log 

Set 

(complete) 

10000470 

10000023 

10000024 

 

1a 

Log - Front left 

BA2 

BB6 

BC5 

 

1b 

Log - Front right 

BA3 

BB7 

BC6 

 1c Log 

rear 

BA4 

BB8 

BC7 

 1d Log 

Top 

left 

BA5 

BB9 

BC8 

 1e Log 

Top 

right 

BA6 

BB10 

BC9 

 * Lava 

rock 

package 

10001454 

10001454 

10001454 

 * Ember 

material 

51915 

51915 

51915 

 

2a 

Burner housing with tiles, Nat. (Includes 2c) 

10002407 

10000031 

10000033 

 

2b 

Burner housing with tiles, Prop. (Includes 2c) 

10002407 

10000032 

10000034

 

2c 

log support bracket - each 

10002942 

10002942 

10002942

 * Ceramic 

tile, 

single 

57803 

57803 

57803 

 

Orifice, burner, Nat and Prop.                                         See the rating plate for orifice specifications

 3a Pilot 

assembly, 

SIT 

RN 

N/A 

10000674 

10000674 

 3b Pilot 

assembly, 

SIT 

RP 

N/A 

10000675 

10000675 

 

4a 

Pilot assembly, SIT Top Convertible RN 

10002264 

N/A 

N/A 

 

4b 

Pilot assembly, SIT Top convertible RP 

10002265 

N/A 

N/A 

 5 Pilot, 

SIT 

N/A 

10001295 

10001295 

 6 Pilot,, 

SIT 

Top 

convertible 

10002266 

N/A 

N/A 

 * Pilot 

orifice, 

SIT 

Nat. 

N/A 

54273 

54273 

 * Pilot 

orifice, 

SIT 

Prop. 

N/A 

54272 

54272 

 

Pilot orifice, SIT Top convertible Nat. 

10002268 

N/A 

N/A 

 

Pilot orifice, SIT Top convertible Prop. 

10002269 

N/A 

N/A 

 

Pilot hood, SIT Top convertible 

10002385 

N/A 

N/A 

 

Thermocouple, RN & RP 

53373 

53373 

53373 

 

Thermopile, RN & RP 

51827 

51827 

51827 

 

10 

Pilot tube (with fittings 

10001296 

10001296 

10001296 

 

Manifold tube (with fittings) 

57318 

57318 

57318 

 

11 

Electrode igniter SIT (with cable), RN & RP 

10001297 

10001297 

10001297 

 12 Piezo 

igniter, 

SIT 

820 

Valve 

52464 

52464 

52464 

 13 Piezo 

igniter, 

Honeywell 

Valve 

20000062 

N/A 

N/A 

 14a Gas 

Valve 

SIT820 

RN 

52677 

52677 

52677 

 14b Gas 

Valve 

SIT820 

RP 

52678 

52678 

52678 

 15a Gas 

Valve 

Honeywell 

RN 

10001782 

N/A 

N/A 

 15b Gas 

Valve, 

Honeywell 

RP 

10001759 

N/A 

N/A 

 

 

16 

Fan assembly (with bracket) (FK24 option) 

54103 

54103 

54103 

 

Electrical cord, (FK24 option). 

51865 

51865 

51865 

 

Fan temperature sensor, (FK24 option) 

51704 

51704 

51704 

 

Fan speed control, (FK24 option) 

51738 

51738 

51738 

Summary of Contents for DBT33

Page 1: ...y electric switch Do not use any phone in your building Immediately call yourgas supplier from your neighbours phone Follow the gas suppliers instructions If you cannot reach your gas supplier call th...

Page 2: ...tion Instructions General Venting Information Terminal Location 9 Connecting Direct Vent Components 11 How To Use The Vent Graph 11 Vertical sidewall Applications 12 Vertical sidewall Installations 13...

Page 3: ...or decorations be hung on or around the replace 9 Under no circumstances should any solid fuels wood coal paper or cardboard etc be used in this replace 10 The ow of combustion and ventilation air mu...

Page 4: ...56 mm 14 406 mm 16 406 mm 16 G 810 mm 31 89 946 mm 37 25 946 mm 37 25 H 152 mm 6 181 mm 7 13 190 mm 7 5 I 149 mm 5 87 171 mm 6 75 159 mm 6 25 J 200 mm 7 87 254 mm 10 213 mm 8 38 K 297 mm 11 343 mm 13...

Page 5: ...rojects out 12 305 mm or more from the front of the replace Cold climate Installation Recommendation When installing this unit against a non insu lated exterior wall or chase it is mandatory that the...

Page 6: ...S SPECIFICATIONS Max Min Input Input Model Fuel Gas Control BTU h BTU h DBT33RN Nat Millivolt 15 000 10 500 DBT33RP Prop Millivolt 15 000 11 250 DBT36RN Nat Millivolt 18 000 12 600 DBT36RP Prop Milliv...

Page 7: ...necessary to provide a 1 8 test point up stream of the control When using copper or ex connectors use only approved t tings Always provide a union when using black iron pipe so that the gas line can...

Page 8: ...alignment Take care not to damage the thermocouple thermopile or igniter 9 SIT 820 NOVA Gas Control Valve Fig 9 a Using a Torx T20 or slotted screwdriver remove and save the three pressure regulator m...

Page 9: ...air supply inlet 72 inches 1828mm minimum L clearance above paved side walk or a paved driveway located on public property 84 inches 2133mm mini mum M clearance under veranda porch deck 12 inches 305...

Page 10: ...DBT33 DBT36 DBT39 10 10002789 0 Fig 11 Fig 12 Fig 13 Fig 14 Fig 15...

Page 11: ...s with three sheet metal screws Fig 16 Wipe off excess sealant CANADIAN INSTALLATIONS The venting system must be installed in accordance with the current CAN CGA B149 1 or 2 installation code U S A IN...

Page 12: ...m number of 90 elbows per side wall instal lation is three 3 If a 90 elbow is tted directly onto the replace ange the maximum horizontal vent run before the termination is 36 914 mm If a 90 elbow is u...

Page 13: ...restop with 8 sheet metal screws supplied Install restop assembly Fig 23 Zero clearance sleeve is only required for combustible walls STEP 3 Place replace into position Fig 24 Measure the vertical hei...

Page 14: ...positioned BELOW GRADE INSTALLATIONS When it is not possible to meet the required vent terminal clearances of 12 305mm above grade level a snorkel vent kit is recommended It allows installation depth...

Page 15: ...H THE ROOF APPLICATIONS This Gas Fireplace has been approved for Vertical installations up to 40 12 m in height Up to a 10 horizontal vent run can be installed within the vent system using a maximum o...

Page 16: ...e MUST BE FITTED TO THE APPLIANCE at installation Fitting The Restrictor Plate 1 Remove the window glass frame assembly 2 Locate the rebox baf e assembly in the top rear area of the rebox Fig 32 3 Rem...

Page 17: ...ion and secure Fig 35 7 Install roof support Fig 36 and roof ashing making sure upper ange of ashing is below the shingles Fig 37 8 Install appropriate pipe sections until the venting is above the ash...

Page 18: ...ation Offsets 90 transition elbow kit 7DVRT90 for Vertical Sidewall Applications or thru the roof Telescopic vent sections 7DVP610 6 to 10 adjustable length 7DVP1018 10 to 18 adjustable length 7DVP183...

Page 19: ...llation 45 elbow kit 7TDV45 for Vertical Installation Offsets 90 transition elbow kit 7TDV90 for Vertical Sidewall Applications or thru the roof Telescopic vent sections 7TDVP1218 12 to 18 adjustable...

Page 20: ...th lemon oil Do not use water or household cleaners on any brass components LOUVRE REMOVAL The top louvre panel is removed by lifting the panel vertically and pulling it away from the appliance Fig 39...

Page 21: ...he right support bracket located over the burner housing and place the log in position 6 Place the left top log in position by aligning the hole on the underside of the log with the lug on the top fac...

Page 22: ...ar the centre of the gas control valve Fig 44 45 FLAME CHARACTERISTICS It is important to periodically perform a visual check of the pilot and burner ames Compare them to the pictorials illus trated b...

Page 23: ...gas go to the next step 7 Remove glass door before lighting pilot See Glass Frame Removal in manual 8 Visibly locate pilot by the main burner 9 Turn knob on gas control counter clockwise to PILOT nei...

Page 24: ...DBT33 DBT36 DBT39 24 10002789 0 TROUBLE SHOOTING THE GAS CONTROL SYSTEM HONEYWELL MILLIVOLT VALVE...

Page 25: ...pplied must be used to conduct this test 3 Pilot burning no gas to A Wall switch or wires defective Check wall switch and wires for proper connections main burner Jumper wire across terminals at wall...

Page 26: ...Pilot assembly SIT Top convertible RP 10002265 N A N A 5 Pilot SIT N A 10001295 10001295 6 Pilot SIT Top convertible 10002266 N A N A Pilot ori ce SIT Nat N A 54273 54273 Pilot ori ce SIT Prop N A 542...

Page 27: ...0002822 10001781 10002821 Gasket window glass 57317 57317 57317 19 Clamp window frame assembly 54174 54174 54174 20 Window trim polished brass with magnets 55005 57480 57483 21 Top louvre assembly 100...

Page 28: ...DBT33 DBT36 DBT39 28 10002789 0 PARTS PICTORIAL...

Page 29: ...he white wire of the power line to the chrome screw of the socket assembly 8 Connect the black wire of the power supply line to the brass screw polarized of the socket assembly 9 Re t the socket assem...

Page 30: ...trol will require suitable extension of the component wiring 4 The power supply may be connected in 2 ways Method A Route the 6 lead tted to the unit to a conveniently located wall socket Method B The...

Page 31: ...efractory panels into place to hold the rear panel secure Adjust the top adjustable tabs to hold the side panel against the rebox wall and secure the tab Repeat the procedure on the other side 8 Repla...

Page 32: ...ssemble the Bay Window Kit according to the instruc tions supplied with the kit 5 Place the 2 pieces of ceramic refractory along the base of the bay window Fig 59 6 Hang the Bay Window Assembly over t...

Page 33: ...10002789 0 33 DBT33 DBT36 DBT39...

Page 34: ...VEAU FOYER AU GAZ AJESTIC NC CONTRE TOUS D FAUTS DE FABRICATION ET DE MATI RES PREMI RES POUR UNE P RIODE DgUN AN COMPTER DE LA DATE DgINSTALLATION SUJET AUX CONDITIONS ET LIMITATIONS SUIVANTES 2 4 6...

Reviews: