DBT33/DBT36/DBT39 -16-
10002789/0
•
7DVCS must be used to support offsets. (Fig. 36)This
application will require that you first determine the roof
pitch and use the appropriate starter kit. (See Venting
Components List)
•
The minimum height of the vent above the highest point
of penetration through the roof is 2'. See Fig. 38.
V
ERTICAL
R
ESTRICTOR
P
LATE
(DBT33
ONLY
)
When installing the DBT33 with a Vertical Through-The-Roof
configured flue system the restrictor plate, (#10002495) sup-
plied with the appliance
MUST BE FITTED TO THE
APPLIANCE
at installation
.
Fitting The Restrictor Plate
1. Remove the window glass/frame assembly.
2. Locate the firebox baffle assembly in the top rear area of
the firebox, Fig. 32.
3. Remove the four (4) nuts along the front edge, and the
three (3) screws along the rear edge of the baffle assembly.
Remove the baffle assembly from the firebox.
4. Remove the two (2) screws from the top face of the baffle
assembly, Fig. 32. Place the restrictor plate as shown in
Fig. 34 and secure by refitting the screws.
5. Refit the baffle assembly to the firebox, replacing the three
(3) screws and four (4) nuts.
6. Refit window glass/frame as per the appropriate sections
of this manual.
Fig. 31
Fig. 32
Fig. 33
Fig. 34