DVB Series Direct Vent Gas Fireplace
38
54D0701
sIGNAtuRe coMMAND - checK GAs pRessuRe and electRIcAl INstAllAtIoN
1. Check gas type. The gas supply must be the same as
stated on the appliance’s rating decal. If the gas supply
is different from the fireplace,
stop!
Do not install the
appliance. Contact your dealer immediately.
2. To ease installation, a 24" (610 mm) flex line with
manual shut-off valve has been provided with on this
appliance. Install and attach 1/2" gas line onto shut-off
valve.
3. After completing gas line connection, purge air from
gas line and test all gas joints from the gas meter to
the fireplace for leaks. Use a solution of 50/50 water
and soap solution or a gas sniffer.
4. To check gas pressures at valve, turn captured screw
counter clockwise 2 or 3 turns and then place tubing
to pressure gauge over test point. Turn unit to high.
Figure 51.
After taking pressure reading, be sure and
turn captured screw clockwise firmly to reseal. Do not
over torque. Check test points for gas leaks.
Figure 51 -
Signature Command Valve
FP1909a
signature command valve
alternate view
8/08
Pressure Inlet
Pilot Adjust-
ment Screw
Pressure Outlet
W
ARNING
Do not use open flame to check for
gas leaks.
electRIcAl WIRING
This fireplace will work without any electrical supply. Electricity is only needed to operate blower.
NOTE: If installed in mobile home, fireplace must be bolted securely to floor.
W
ARNING
electrical connections should only
be performed by a qualified, licensed
electrician. Main power must be off when
connecting to main electrical power supply
or performing service. All wiring shall be
in compliance with all local, city and state
codes. the appliance, when installed, must
be electrically grounded in accordance with
local codes or in the absence of local codes,
with the National electrical code ANsI/NFpA
70 (latest edition) and canadian electrical
code, csA c22.1.
c
A
ut
Io
N
label all wires before disconnecting
when servicing controls. Wiring errors
can cause improper and dangerous
operation.
Verify proper operation after servicing.