© MAHLE
12 | ACX2120H | Technical features
en
3.6
Functional description
The refrigerant recovered from the air conditioning system passes
through the combo ter to remove suspended particles and
moisture.
The purpose of the vacuum pump is to generate a vacuum in
the air conditioning system which removes excess moisture and
to detect possible leaks in the vehicle air conditioning system.
Used oil is separated from the recovered vehicle refrigerant and
drained into the used oil bottle.
The vehicle air conditioning system is partly lled with
UV dye to facilitate the detection of leaks in the event of damage
to the vehicle air conditioning system.
The refrigerant in the internal refrigerant bottle is used for
the vehicle air conditioning system.
The purging unit for the non-condensable gases, consisting of
a temperature sensor, pressure sensor, coil and
always
takes
when the internal refrigerant bottle pressure is higher
than the saturation pressure.
4.
Technical features
Description
R134a tank capacity
12L
Service pressure
400PSI
Maximum content
22lbs
Method to weigh gas content
Load cell
Recovered oil container
250ml
Vacuum pump
2CFM dual stage
Vacuum pump oil quantity
250ml
Compressor capacity
0.87cu in/14cc
Dr
ter
75kg of recovered R134a
Non-condensible gas purge
Automatic via solenoid valve
HP and LP taps
Automatic
Display
LCD monochrome FSTN 240x64 dots
Keypad
Membrane
Software updating
USB type A or USB type B direct con -
nect to PC
Printer (optional)
Thermal, 24 columns
All functions
Automatic and manual
Recycling mode
Single or multipass
Memory for customized cycles
100 records
Flushing
With integrated solenoid valves
System pressure diagnostics
Manual and automatic
Dr
ter replacement alarm
Active
Vacuum pump oil replacement
alarm
Active
Full/empty tank check alarm
Active
Full oil container check alarm
Visual
Empty oil container alarm
Visual
Dimension HxWxD
119 x 74 x 74 cm
Dry weight
98kg
Power supply frequency
60Hz
Voltage
120VAC, 1 phase
Total max load
7.5A
Overcurrent protection
12A (circuit breaker)
Operating temperature
50-122°F
Humidity
10-90%RH (non condensing)
Storage temperature and hu -
midity
-13 to 50°F
10-90%RH (non condensing)
Max operating altitude
6562ft
Pollution degree
2
Water degree
0
Cer
SAE J2788
UL1963
CAN/CSA STD C22.2 NO. 120-M91