38
BA322301-en
LED code
Status/ Note / Error
Remedy
RED
YELLOW
GREEN
---
Flashes 5x Lights
Ceiling light barrier
(optional)
Remove obstacles in the
light barrier.
In case of recurrence,
contact MSC.
Flashes 6x Lights
Liquid detector (optional)
Check the installation
cassette for water
ingress and pump it out
if necessary.
In case of recurrence,
contact MSC.
---
Flashes 7x ---
Emergency stop switch
Remote control (optional)
Unlock emergency stop
switch.
In case of recurrence,
contact MSC.
Lights
Flashes 8x ---
Motor temperature
Allow the hydraulic unit
to cool down.
In case of recurrence,
contact MSC.
Lights
Flashes 9x ---
Switch monitoring “Lift up”
Replace “Lift up” sensor.
In case of recurrence,
contact MSC.
Lights
Flashes 10x ---
Switch monitoring
“CE
stop”
Replace “Lift up” sensor.
In case of recurrence,
contact MSC.
---
---
Lights
Service interval expired
Contact MSC.
*MSC = MAHA Service Center