124
BA053101-en
Pos: 430 /Technis che Dok umentation/A lle G eräte/ Überschr iften/Üb erschriften 1.1/S/ Überschr ift 1.1: Sensor M odule C abinet 30 (SMC 30) @ 17\mod_ 1253261887787_75.d ocx @ 444645 @ 2 @ 1
16.4
Sensor Module Cabinet 30 (SMC30)
Pos: 431 /Technis che Dok umentation/ Leis tungsmesstechnik/POWE RDYNO/053101 M SR/ BA/Inhalt: 0531 SINAMICS Sensor M odule Cab inet 30 (SMC 30) @ 17\mod_ 1253261947128_ 75.docx @ 444732 @ @ 1
LED
Color
Status
Description, Cause
Remedy
RDY
READY
-
Off
Electronics power supply is missing or outside
permissible tolerance range.
-
Green
Steady
light
The component is ready for operation and cy-
clic DRIVE-CLiQ communication is taking place.
-
Orange
Steady
light
DRIVE-CLiQ communication is being estab-
lished.
-
Red
Steady
light
At least one fault is present in this component.
Note:
LED is driven irrespective of the corresponding
messages being reconfigured.
Remedy and ack-
nowledge fault
Green / Red
Flashing
Firmware is being downloaded.
-
Green /
Orange
or
Red / Orange
Flashing
Component recognition via LED is activated
(p0144).
Note:
Both options depend on the LED status when
component recognition is activated via p0144 =
1.
-
OUT > 5V
-
Off
Electronics power supply is missing or outside
permissible tolerance range.
Power supply > 5 V.
-
Orange
Steady
light
Electronics power supply for measuring system
available.
Power supply > 5 V.
Notice:
You must ensure that the connected encoder
can be operated with a 24 V supply. If an en-
coder that is designed for a 5 V supply is oper-
ated with a 24 V supply, this can destroy the
encoder electronics.
-
Pos: 432 /-----Format- ----/MANUE LLE R UMBRUCH Seitenumbruch @ 0\mod_ 1134403577687_0.docx @ 1277 @ @ 1