RATE ADJ RESET
Used to reset the Rate Adjustment back to the default value of 1.0000. This can be helpful if changing materials and
the new material has a different consistency than the original material. When reset it may help the MGF to re-learn
the rate quicker then if it adjusted the rate from the previously learned value.
Press
To scroll down to
SETUP
(using arrow key)
Press
ENTER
Display will say:
ENTER PASSWORD _ _ _ _
Enter
2222
Default password is 2222
Press
9 times to scroll the display down to RATE ADJ RESET
Press
ENTER
to display the Rate Adjust Reset screen. This screen will display the OLD
ADJ and the NEW ADJ. OLD ADJ is the Rate adjustment that the MGF
learned based on the material that was running through the MGF. NEW
ADJ is the base number of 1.0000. Resetting this number back to 1.0000
when new material is used may help the MGF re-learn the Rate
Adjustment quicker. If the new material has the same consistency as the
original material, this step is not necessary.
Press
ENTER
to reset the Rate Adjustment back to 1.0000.
Press
BACK
three more times to exit SETUP and go back to the Main Screen
SET MODEL (MGF-3, MGF-4, MGF-8)
Used to set the model and auger size. MGF-3 is used a 3/8 inch auger, MGF-4 is used for a 1/2 inch auger, MGF-8 is
used for a 1 inch auger. PRIME FUNCTION is required after a model Change.
Press
To scroll down to
SETUP
(using arrow key)
Press
ENTER
Display will say:
ENTER PASSWORD _ _ _ _
Enter
9753
Password to set the model. Display will show the current model.
Press
ENTER
to change the model. Model options are:
MGF-3 – 3/8 inch auger
MGF-4 – 1/2 inch auger
MGF-8 – 1 inch auger
Press
BACK
three more times to exit SETUP and go back to the Main Screen
Power off, then power on the controller to verify that the model has been changed.
IMPORTANT: After a model change a PRIME FUNCTION is required to calibrate the MGF. See
page 14 for Prime Function Instructions.
NOTE: For older controllers that do not respond to the password 9753, model change is access
under SETUP / SETTINGS / MODEL. Press ENTER to change the model and BACK to exit.
Summary of Contents for GRAVIMETRIC AUGER FEEDER MGF-ST
Page 39: ...M A G U I R E P R O D U C T S I N C 39 G R A V I M E T R I C A U G E R F E E D E R ...
Page 40: ...M A G U I R E P R O D U C T S I N C 40 G R A V I M E T R I C A U G E R F E E D E R ...
Page 42: ...M A G U I R E P R O D U C T S I N C 42 G R A V I M E T R I C A U G E R F E E D E R ...
Page 43: ...M A G U I R E P R O D U C T S I N C 43 G R A V I M E T R I C A U G E R F E E D E R ...
Page 44: ...M A G U I R E P R O D U C T S I N C 44 G R A V I M E T R I C A U G E R F E E D E R ...
Page 46: ...M A G U I R E P R O D U C T S I N C 46 G R A V I M E T R I C A U G E R F E E D E R ...
Page 47: ...M A G U I R E P R O D U C T S I N C 47 G R A V I M E T R I C A U G E R F E E D E R ...