19
G R A V I M E T R I C A U G E R F E E D E R
MODE - Select Mode of Operation – CYCLE, CONTINUOUS or EXTR FLLW
Turn the MGF Power ON. Power button located on lower left side of controller.
View the LCD window. Allow controller to boot up to MAIN MENU.
Press
To scroll down to
SETUP
(using arrow key)
Press
ENTER
Display will say:
ENTER PASSWORD _ _ _ _
Enter
2222
Default password is 2222
Press
ENTER
to enter SETTINGS. Display will show SETTINGS options.
Press
once, scrolling the display down to MODE.
Press
ENTER
to toggle between CYCLE, CONTINUOUS and EXTR. FLLW
(Extrusion Following) Mode.
Select CYCLE...
for injection molding, where the MGF auger turns on and off with
each cycle. In this mode the first step is to enter the
SHOT
WEIGHT
of the part on the main screen. Next set the
LDR
(Let
Down Ratio) on the main screen. In CYCLE mode your MGF will
dispense the calculated rate (shot weight x LDR) during the
length of screw recover time.
Select CONTINUOUS...
for extrusion, where the MGF auger runs continuously. In this
mode the first step is enter
LBS (or KILOS) / HOUR
of the
extruder on the main screen. Next set the
LDR
(Let Down Ratio)
on the main screen. In CONTINUOUS mode your MGF will run
continuously at the calculated rate (lbs/hr x LDR). Auger speed
will adjust automatically to maintain dispense rate.
Select EXTR. FLLW...
for extrusion, where the MGF auger runs continuously by
following the 0-10 volt reference voltage of the extruder screw.
In this mode the first step is to set the XMO parameter. Setting
XMO will automatically calculate extruder throughput on the main
screen based on a 0-10 volt reference. See page 27 for XMO.
Next set the
LDR
(Let Down Ratio) on the main screen. In
Extrusion Following mode your MGF will run continuously at the
calculated rate (lbs/hr x LDR). Auger speed will adjust
automatically to maintain dispense rate.
With the correct mode selected...
Press
BACK
to select the mode of operation you will use.
Press
BACK
Twice more to exit SETUP and back to the Main Screen
Summary of Contents for GRAVIMETRIC AUGER FEEDER MGF-ST
Page 39: ...M A G U I R E P R O D U C T S I N C 39 G R A V I M E T R I C A U G E R F E E D E R ...
Page 40: ...M A G U I R E P R O D U C T S I N C 40 G R A V I M E T R I C A U G E R F E E D E R ...
Page 42: ...M A G U I R E P R O D U C T S I N C 42 G R A V I M E T R I C A U G E R F E E D E R ...
Page 43: ...M A G U I R E P R O D U C T S I N C 43 G R A V I M E T R I C A U G E R F E E D E R ...
Page 44: ...M A G U I R E P R O D U C T S I N C 44 G R A V I M E T R I C A U G E R F E E D E R ...
Page 46: ...M A G U I R E P R O D U C T S I N C 46 G R A V I M E T R I C A U G E R F E E D E R ...
Page 47: ...M A G U I R E P R O D U C T S I N C 47 G R A V I M E T R I C A U G E R F E E D E R ...