M A G U I R E P R O D U C T S , I N C .
23
G R A V I M E T R I C A U G E R F E E D E R
Print Options – Send a Parameter report to the USB Drive, Print a report every
X
minutes.
Press
To scroll down to
SETUP
(using arrow key)
Press
ENTER
Display will say:
ENTER PASSWORD _ _ _ _
Enter
2222
Default password is 2222
Press
to scroll the display down to PRINT OPTIONS.
Press
ENTER
to enter PRINT OPTIONS.
Press
to select either
Parameters
or
Report Interval
.
Selecting
Parameters
and pressing
ENTER
will cause a Parameters Report to be
send to the USB drive. Selecting
Report Interval
will allow time in minutes to be set for
in Continuous or Extrusion Following Mode (001 to 999) or enabling of cycle reports by
printing every cycle when enabled. 001 enable cycle reports. The MGF will append a
snapshot of current information to a file on the USB drive. See below for details on the
Reports
. NOTE: There must be a folder named "maguire" on the USB key for the
print job to write the file MGFCYCLE.TXT within that folder.
Also see PRT
parameter.
Press
BACK
two times to exit SETUP and go to the Main Screen
Example of a Parameters Report:
FIRMARE: J0323A
GRAVIMETRIC FEEDER ID# 000 WO 000000 RECIPE 00000 OP 000 MODEL 50
IP ADDRESS:192.168.0.1 SUBNET:255.255.255.0 GATEWAY:0.0.0.0
MODE: CYCLE
GENERAL PARAMETERS
NAME RAM ROM
LDR 500 200
SHT 500 200
PHR 2 200
FUL 3500 3500
PRT 1 0
KDF 6 6
LCZ 583 583
MTF 136 75
XCV 2 0
XRC 40 40
XAL 5 5
XUL 200 200
XMO 1000 1000
LBE 30 30
UBE 300 300
NBW 100 100
LWA 400 400
ATP 50002 51005
RTU 305 305
ADJ 3005 3005
LLF 500 500
LHF 2000 2000
LAT 120 120
STL 10 10
NWA 100 100
XMR 0 0
Interval Report in Cycle Mode
07/27/2013 15:40:56
GRAVIMETRIC FEEDER ID# 000 WO 00000 RECIPE 00000 OP 000
LDR: 5.00% SHOT WT: 69.0g TOT: WT: 37.2
WEIGHT: 3402.1 ON TIME: 171ms TOT. CT: 12
AVG. DISP 2.98 RATE ADJ: 0.8145
TARGET: 3.45 ACC. WT: 17.89
ERROR: -2.8 (3) ACC. CT: 6
SIG ON: 8.07s
07/27/2013 15:40:56
Date and Time of this cycle printout.
Interval Report in Continuous Mode
07/27/2013 15:40:56
GRAVIMETRIC FEEDER ID# 000 WO 000000
RECIPE 00000 OP 000
LDR: 2.00% LBS/HR: 200
WEIGHT: 1784.7 ON TIME: 360ms
DISPENSED: 30.9 RATE ADJ: 1.0281
TARGET: 30.2 TOTAL: 429.8
ERROR: +0.6 (2%) REFILL CT: 157
07/27/2013 15:40:56
Date and Time of this cycle printout.
To the left is an example of a parameters report. This report
prints the current parameter settings loaded into RAM (those
that are currently in use) as well as parameters in ROM (factory
defaults), current firmware version, MGF model, current mode
of operation, and communications specific settings (ID#, IP
address, subnet, gateway). Also available is work order
number, recipe number and operator number which are set via
the MLAN protocol.
Below are the output reports produced during the preset time
interval. These reports display a date / time stamp, the MGF ID
number, Work Order #, Operator #, and Recipe #, the current
settings, current hopper content weight, on-time, dispensed
weight, rate adjustment, target, total weight dispensed in 10ths
of grams, error %, cycle count (cycle mode) refill of the hopper
count, and signal indicator with a signal count in seconds.
Summary of Contents for GRAVIMETRIC AUGER FEEDER MGF-ST
Page 39: ...M A G U I R E P R O D U C T S I N C 39 G R A V I M E T R I C A U G E R F E E D E R ...
Page 40: ...M A G U I R E P R O D U C T S I N C 40 G R A V I M E T R I C A U G E R F E E D E R ...
Page 42: ...M A G U I R E P R O D U C T S I N C 42 G R A V I M E T R I C A U G E R F E E D E R ...
Page 43: ...M A G U I R E P R O D U C T S I N C 43 G R A V I M E T R I C A U G E R F E E D E R ...
Page 44: ...M A G U I R E P R O D U C T S I N C 44 G R A V I M E T R I C A U G E R F E E D E R ...
Page 46: ...M A G U I R E P R O D U C T S I N C 46 G R A V I M E T R I C A U G E R F E E D E R ...
Page 47: ...M A G U I R E P R O D U C T S I N C 47 G R A V I M E T R I C A U G E R F E E D E R ...