3 - Command Set
DynaPro Mini| PIN Encryption Device | Programmer’s Manual (Commands)
Page 43 of 128 (
D99875629-43
)
If an error occurs, the device will terminate the command and report the error in ACKSTS of
. For a full list of error codes, see
Appendix C Status and Message Table, Table
Table 3-14 - Usage Table for Command 0x0D (For PAN)
Bit
7
6
5
4
3
2
1
0
Byte 0
0x0D
Byte 1
0x01
Byte 2
String length of PAN data: 8-19
Byte 3..21
PAN data in ASCII format
3.4.14
Command 0x0E - Get Information
The host uses this command to retrieve various types of information from the device.
Table 3-15 - Usage Table for Command 0x0E
Bit
7
6
5
4
3
2
1
0
Byte 0
0x0E
Byte 1
If the host is using any Info Id other than 0x80, it should follow these steps:
1)
Call this command in Set mode, specifying the Info ID from
. If an error occurs, the
device will terminate the command and report the error in ACKSTS of
. For a full list of error codes, see
Appendix C Status and Message Table, Table 3-76
2)
Call this command in Get mode with the same parameters.
3)
The device responds with the requested data.
If the host is retrieving Info ID 0x80, the host should simply call this command in Get mode, and if the
device has keys injected, the command will return the KCV/Hash value of the last injected key or
certificate.
Table 3-16 - Usage Table for Command 0x0E
Bit
7
6
5
4
3
2
1
0
Byte 0
0x0E
Byte 1
Byte 2
Key Status, if Info ID < 0x80:
0 = Empty (default)
1 = OK
2 = Exhausted
Key Status, if Info ID = 0x80:
0 - 5 = KCV type (see
Byte 3
Data length (see
); default value is 0