background image

OPERATING GUIDE for your

 

GEM-RP1CAe2 KEYPAD 

© NAPCO 2000 

DESIGN PATS. PENDING 

ARMED

 

COMPUTERIZED SECURITY SYSTEM 

STATUS

 

G E M I N I  

 

A   1   2   3  

 

B   4   5   6  

 

C   7   8   9   0  

SYSTEM ARMED

SYSTEM ARMED  

1122/01/

/01/00

00   12:00 AM

   12:00 AM  

NEXT/YES 

E

 

PRIOR/NO 

F

 

AREA 

G

 

Summary of Contents for GEM-RP1CAe2

Page 1: ...your GEM RP1CAe2 KEYPAD NAPCO 2000 DESIGN PATS PENDING ARMED COMPUTERIZED SECURITY SYSTEM STATUS GEMINI A 1 2 3 B 4 5 6 C 7 8 9 0 J SYSTEM ARMED SYSTEM ARMED 1 12 2 01 01 00 00 12 00 AM 12 00 AM NEXT YES E PRIOR NO F AREA G ...

Page 2: ...y check its condition and state of readiness by testing it at least once a week in both the ac battery and battery only modes ask your alarm professional how to make these tests INTRODUCTION Test your sounding device and backup battery This test should only be performed on weekends or at a time designated by your alarm company 1 While disarmed press A 2 Answer NO press F until ACTIVATE BELL TEST a...

Page 3: ...G USER CODES 22 SETTING THE DATE AND TIME 22 KEYPAD MESSAGES 26 GLOSSARY 29 SYSTEM TROUBLE ERROR CODES 32 TROUBLESHOOTING 37 TO SILENCE AN ALARM ENTER YOUR CODE AND PRESS J FOR SERVICE CALL _____________________ CENTRAL STATION ______________________ EXIT DELAY _____________________________ ENTRY DELAY ___________________________ FIRE ALARM SOUND _____________________ BURGLAR ALARM SOUND _________...

Page 4: ...NTROLS INDICATORS 1 2 3 4 5 6 7 12 8 9 10 11 ARMED COMPUTERIZED SECURITY SYSTEM STATUS GEMINI A 1 2 3 B 4 5 6 C 7 8 9 0 J SYSTEM ARMED SYSTEM ARMED 01 01 00 12 00 AM 01 01 00 12 00 AM NEXT YES E PRIOR NO F AREA G ...

Page 5: ...stem troubles displays etc See text 2 Resets residential smoke detectors Numerical Keys 1 9 0 Used to enter codes zone numbers etc ON OFF Button Entry key Causes the entered code or selected function to be executed INTERIOR Button 1 Bypasses all Interior Zones simultaneously to allow free movement within the premises 2 Scrolls the window display forward NEXT 3 Answers YES to questions in the windo...

Page 6: ... the keypad will display INVALID ENTRY TRY AGAIN Re enter your code immediately Leave the premises Leave through the exit door before exit time expires Priority Arming If you attempt to arm with a faulted Zone a 3 second tone will sound at the keypad ZONES NOT NORMAL and CAN T ARM SYSTEM will display in the window indicating that the faulted zone s must be secured before the panel can be armed Sel...

Page 7: ...a partitioned system To arm disarm a different area 1 Press the numerical key representing the other area number 2 Press G followed byJ The keypad will now provide status and control of that area 3 Enter your User Code followed by J to arm or disarm the area 4 Press G followed byJ to return to the home area Global Arming Optional To arm all areas simultaneously press 9 G and enter your code follow...

Page 8: ...emained in the house prompting it to automatically adjust the interior protection accordingly If you arm the system and remain in the house all Interior Zones are automatically bypassed The keypad will display BYPASSED indicating that it is safe to move about If the system is armed and you leave the Interior Zones will unbypass providing complete interior protection Instant Protection When retirin...

Page 9: ...GEM P1632 V8G or less q Press J to activate Easy Exit on your system GEM P3200 GEM P9600 V20 or greater GEM P816 P1632 V9A or greater Emergency Buttons Only available if programmed The Blue Emergency Buttons 7 7 8 8 9 9 if programmed are always active whether the system is armed or disarmed The emergency signal will only be transmitted when an Emergency Button and G G are pressed at the same time ...

Page 10: ...a neighbor s phone To silence an audible alarm Enter your code and press J After the system is disarmed the window will continue to display ALARM followed by the zone s violated To reset the display note the zones violated then press C TURNING OFF THE ALARM DISARMING WHEN RETURNING ENTRY TIME XXX DISARM SYSTEM INVALID ENTRY TRY AGAIN ALARM 02 BACK ALARM 03 LIVING ROOM Ambush Optional Ambush progra...

Page 11: ...l the Fire Department from an outside phone FIRE FIRE ALARM FIRE FIRE TROUBLE Resetting a Fire Zone Alarm 1 Press the C button to silence the keypad sounder 2 If there is no evidence of a fire enter your User Code and pressJ to turn off the alarm Check smoke detector s If a smoke detector tripped its red alarm indicator light will be on After the alarm condition is corrected thermostat cooled down...

Page 12: ... with all those who use the building In a residence sleep with the bedroom door closed A closed door will hold back deadly smoke while you escape 2 When the fire alarm signals escape quickly Do not stop to pack 3 Test the door If it is hot use your alternate route through the window If the door is cool brace your shoulder against it and open it cautiously Be ready to slam the door if smoke or heat...

Page 13: ...13 FIRE PROTECTION Floorplan Floorplan ...

Page 14: ...res because the fire may be a slow smoldering low heat type producing smoke because they may not be near the fire or because the heat of the fire may bypass them These detectors will not detect oxygen levels smoke toxic gases or flames Therefore they may only be used as part of a comprehensive fire detection system in conjunction with other devices Under no circumstances should thermostatic heat d...

Page 15: ...ng A and B respectively To return to normal keypad operation press the C button The keypad will automatically return to its normal operating mode if no activity is detected for longer than one minute Display Zone Faults Displays the zone number of zones that are not secured Press the NEXT and PRIOR Buttons as displayed on screen to scroll faulted zones Display Zones Bypassed Displays bypassed zone...

Page 16: ...s Display Fire Troubles Displays trouble conditions that have been detected on the Fire Zone s Use NEXT E and PRIOR F to scroll zones Activate Chime The Chime Mode will sound a tone at the keypad when the programmed zone is faulted while disarmed To deactivate the Chime Mode re enter the Function Mode and when DEACTIVATE CHIME is displayed press YES E Note The Chime Mode is disabled while armed Ac...

Page 17: ...e sensor in question To reset press C to clear the display enter the Function Menu scroll to RESET SENSOR MSG and pressJ If you cannot correct the problem call for service Start Exit Time Optional Start Exit Time programmed qYES qNO In Commercial Burglary systems exit delay may have been programmed to start after a central station ringback verification signal has been received If the ringback tone...

Page 18: ...1 to 4 hours To Delay Arm the system With the function TO ARM IN 1 4 HRS displayed in the window enter the desired Delay Arming time in hours 1 2 3 or 4 followed by J At the end of this 1 4 hour Delay Arming period the siren will sound a 2 second warning and the keypad will begin a 15 minute arming countdown with the sounder pulsing The sounder may be silenced at this time by pressing C but it wil...

Page 19: ...ed group on or off press NEXT E to proceed to the next group or PRIOR F to scroll back to the previous group Press C when done Relay Group 01 ____________________________________ Relay Group 02 ____________________________________ Relay Group 03 ____________________________________ Relay Group 04 ____________________________________ Relay Group 05 ____________________________________ Relay Group 0...

Page 20: ...y Non 24 Hour Zone Reports are aborted by disarming within the delay period 24 Hour Zones and zones programmed to report restores must be restored first then the panel armed and disarmed all within the delay period Opening and or Closing Reporting Your system can notify the central station every time it is disarmed or armed Any or all of up to 96 different users can each be identified If your syst...

Page 21: ...mmunication problem may exist call for service Function 11 Start Exit Time may then be used to manually start the exit delay however reporting capability may be sacrificed If your system does not report or the ringback feature was not programmed exit delay will start as soon as your code is entered Also note that if an exception window is programmed and the closing is within that window no ringbac...

Page 22: ... for each User Code to be programmed User Program Mode Your Installer has programmed into your system a special User Program Code which can be used to not only Arm and Disarm the system but also to enter the User Program Mode where you can program other User Codes Zone Descriptions and also set the system Time and Date The following explains how you will use this code to program or erase additiona...

Page 23: ...r User No 3 then press A A followed by 3784 5 Press J to save the code 6 Press C to exit the Program Mode Notes If the system contains more than one keypad only the keypad designated No 1 may be used for programming if in doubt which is No 1 ask your installer While in Program Mode the ARMED and STATUS lights remain off and burglar and fire alarm functions are disabled In selecting your codes do n...

Page 24: ...rs punctuation marks and a variety of symbols Use the above buttons to enter each character of the description and then press J to save when the zone description is complete To advance to the next zone or to any other zone Move the cursor to the displayed zone number i e 01 using 1 1 and 2 2 Change the zone number using 3 3 and 6 6 then move the cursor to the first character of the description and...

Page 25: ... 2000 enter 07 29 00 2 PressJ to save the Date Programming the system Date and Time The User Program Mode may also be used to set the system Date and Time which display on the ACTIVATE PROGRAM Y N ENTER DATE 00 00 00 ENTER DATE 07 29 00 ENTER TIME 12 00A ENTER TIME 06 30P Programming the Time 1 After entering in the Date press NEXT E for the Time Entry screen 2 At the Enter Time screen simply punc...

Page 26: ...If displayed S indicates Service Code active I indicates arming with Instant protection Entry delay in progress XXX shows entry time remaining in seconds System armed If displayed I indicates arming with Instant protection Zones not secured doors or windows may be open Faulted zone s will scroll Arming attempted with faulted zone The display will scroll the zone faults Secure the zone s and arm sy...

Page 27: ...n on a Fire Zone Press C to silence sounder Evacuate premises or correct cause of alarm For partitioned systems only Code not valid for area Wrong code entered or Easy Bypass function not enabled In Manager s Mode Arming prevented due to unsecured zone represents number of area with unsecured zone Press area number then the G button then J to view zones in that area Correct problem then arm as nor...

Page 28: ...tes problem s detected on system See examples below and SYSTEM TROUBLE ERROR CODES for a complete list of system troubles and corrective actions Check power transformer Check for blown fuse or circuit breaker general power outage Battery weak If not recharged within 24 hours replace battery Communication failure to central station ATTEMPTING TO CANCEL ALARM CANCELED SYSTEM TRBL LOW BATTERY E02 00 ...

Page 29: ...rough Managers Mode Arming Disarming Turning the system on off by entering your code at the keypad then pressing J Battery Backup power source in the control panel enclosure to provide protection in the event of a power failure BPASS Button Enables you to manually remove one or more protective zones from the system Central Station Monitors incoming reports and emergency messages from a digital com...

Page 30: ... subsystems areas Pre Alarm Warning A keypad sounder alert of an impending alarm This option is programmable by zone for the same duration as that programmed for Abort Delay see Abort Delay Report A transmission to a central station notifying of a change in the status of the system alarm trouble low battery etc RF Low Battery Wireless sys tems only Weak transmitter battery F Check In Wireless syst...

Page 31: ...e disarmed Exit Entry Follower Zone Provides exit and entry delay for interior devices Entry delay only occurs if re entry takes place through the normal exit entry door first Fire Zone Detects fire alarms or trouble conditions Interior Zones Circuits within the premises usually including space protection devices interior doors etc but not exterior doors or windows These can all be bypassed simult...

Page 32: ...alling company for service as soon as possible Trouble Indication System Trouble Condition Action E01 00 AC Power Failure This trouble will occur if AC power is not present Make sure system transformer is plugged into AC receptacle and check the circuit breaker otherwise call installing company for E02 00 Low Battery If there has been a recent power failure the battery may be partially depleted an...

Page 33: ...m 2 required for the GEM PIR and GEM GB The replacement battery for the GEM SMK is the Duracell MN1604 9 Volt Alkaline 2 required The GEM DT Dual Technology Sensor requires 4 C cell alkaline batteries Warning Replace batteries only with the same type as specified above Use of another battery may present a risk of fire or explosion Do not recharge or disassemble battery or dispose of in fire E06 NN...

Page 34: ...dule A problem has been detected E16 NN Wireless Receiver A problem has been detected with the wireless receiver Call installing company for service E17 NN Receiver Tamper Condition Call installing company for service E18 NN KeyFob Transmitter Low Battery The batteries in the wireless KeyFob transmitter indicated are low and should be replaced The replacement battery is the Duracell 386 Lithium ba...

Page 35: ...ear any obstacles which may be blocking the sensor from detecting activity Press C to clear the display and then use the Function Menu to Reset Sensor Watch Failure see page 17 If you cannot correct the problem yourself call installing company for service E23 00 Burglary Bus Failure Call installing company for service E24 00 Service Message The system is in need of a preventive maintenance service...

Page 36: ...n System Trouble Condition Action E41 NN Fire Trouble A problem has been detected on the Fire zone indicated Call installing company for service E51 00 Bell Siren Trouble There is a problem with the Bell or Siren Call installing company for service ...

Page 37: ... the scrolling error codes which represent the trouble Press C and you will now be able arm to the system but the trouble must be fixed as soon as possible See Page 7 28 The Fire Alarm is sounding and I don t know how to turn it off If a fire is in progress evacuate the premises immediately If necessary call the Fire Department from an outside phone If there is no evidence of a fire enter your cod...

Page 38: ...38 NOTES ...

Page 39: ...39 NOTES ...

Page 40: ...ved NAPCO will not be responsible for any dismantling reassembly or reinstallation charges This warranty contains the entire warranty It is the sole warranty and any prior agreements or representations whether oral or written are either merged herein or are expressly canceled NAPCO neither assumes nor authorizes any other person purporting to act on its behalf to modify to change or to assume for ...

Reviews: