32
S Y S T E M T R O U B L E E R R O R C O D E S
Your control panel is capable of detecting a variety of troubles that may affect system performance. In the unlikely event that a
problem should occur, the SYS TBL (system trouble) icon will display on the left side of keypad window along with one or more of
the following error codes. If the problem is related to a specific zone or device, the corresponding number will also be indicated.
Below is a list of the most common troubles along with the necessary corrective action, if any. If a message appears that is not
listed below, call your security professional for service. When a system trouble occurs, the keypad can be silenced and the
display can be cleared by pressing
C
. The system can then be armed and disarmed as usual.
Note:
If you cannot clear a system trouble yourself, call installing company for service as soon as possible.
Trouble
Indication
System Trouble
Condition
Action
E01-00
AC Power Failure
This trouble will occur if AC power is not present. Make sure system transformer is plugged
into AC receptacle and check the circuit breaker, otherwise call installing company for
E02-00
Low Battery
If there has been a recent power failure, the battery may be partially depleted and must be
recharged by the control panel. The control panel performs an automatic daily test of the
battery, at which time the trouble will clear if the battery has been recharged.
If the trouble does not clear in 24 hours, call installing company for service.
E03-00
Communication
Failure
The system was not able to report to central station. If this is due to a temporary interruption
in the telephone service, the trouble can be cleared when the service is restored by
performing a Communication Test:
1 While disarmed, enter your User Code followed by
A
.
1 Answer NO (
F
)
until “ACTIVATE DIALER TEST” appears in the window.