26
CLEANING INSTRUCTIONS…continued
WARNING: DISCONNECT THE POWER CORD BEFORE CLEANING OR SERVICING THIS UNIT.
THE STOVE MUST BE TURNED OFF AND COOLED BEFORE USING THE RAKE HANDLE.
II. HEAT EXCHANGER:
This stove is designed with a built-in heat exchange tube
Rake. The ash handle is located on the front of the stove
and is moved backwards and forwards several times
to remove the buildup of ash. After cleaning, push the
rake handle in until it stops.
III. COMBUSTION BLOWER:
Over the course of the heating season dust and ash may collect on the blades of the combustion blower.
Periodically they should be inspected and vacuumed clean. The combustion blower is accessed by opening the
stove’s right side panel and then removing the inspection caps or the exhaust manifold cover (See figure below).
Never operate the stove without the inspection cap or manifold cover in place.
ASH RAKE HANDLE
Essex Model Shown, All models have a
Ash Rake in the top front grill area
The manual reset thermodisk must
be reset by pushing in on the center
button. This can be tripped when
cleaning the unit or when the unit
overheats.
EXHAUST
MANIFOLD
COVER
HOPPER
REAR EXHAUST
OUTSIDE
AIR
INLET
SIDE PANEL
CAP
INSPECTION
AUTO RESET
150 NORMALLY OPEN
COOL DOWN
HIGH TEMP SHUT OFF
AUGER THERMODISK
AUTO RESET
150 NORMALLY OPEN
PROOF OF FIRE THERMODISK
200 MANUAL RESET
110 deg.
110
Optional Location