19
AC CONTROL PANEL/THERMOSTAT HOOK-UP
WARNING: ALWAYS DISCONNECT POWER CORD DURING ANY ELECTRICAL
OPERATION
1.
Remove control panel from protective packaging.
2.
Connect the one way molex plug to the control panel, do not pull on the wire harness inside the stove.
NOTE: Use only a low voltage mercury or bi-metal thermostat switch. (No power
Required on thermostat)
NOTE: If you are not going to use the thermostat function then skip steps #4 -#8 and go to
Step #9.
3.
Locate the thermostat on a wall six (6’) to (10’) feet away.
4.
Route the wires into the stove near where the AC power cord enters.
5.
Pull the thermostat wire through to the control panel cut-out.
6.
Move the factory installed jumper from the upper position to the lower position. (see details below)
7.
Connect the thermostat wires to the two terminals on the back of the control panel.
When the room temperature drops below the thermostat setting, the thermostat switch will close, allowing the
stove to operate at the medium or higher settings. When the room temperature matches the thermostat setting, the
thermostat switch will open, allowing the stove to operate at the low setting.
8.
Locate the control panel into the side panel cut-out and secure with four (4) #7 X ½ Phillips screws
(supplied). Do not over tighten.
9.
The stove is now ready for operation. Refer to the
OPERATING INSTRUCTIONS
Note: The thermostat function of the stove will
Cycle with the room temperature when the
“Fuel Feed Control” is set at a medium
or higher setting and the switch on the top front of the control panel is set to the T-STAT setting.
LOW VOLTAGE
THERMOSTAT
MERCURY SWITCH
MOLEX
PLUG
.250
TERMINAL
QTY.- 4
#7 x 1/2"
SCREWS
AC POWER CORD
THERMOSTAT JUMPER
MUST BE MOVED TO
THIS POSITION
.250 TERMINAL SPADE
THERMOSTAT WIRE
CONNECTION
MOLEX PLUG
MOLEX PLUG
CONTROL PANEL
Must be in this
position