NOTE:
The viewing door, ash pan door and hopper door must be closed and/or latched during operation or the vacuum will
not be established. If vacuum can not be established the stove will shut down and the #2 heat level setting light will blink.
The ON/OFF button must be pushed and held for app. 6 seconds to reset the system.
The unit starts on a pre-set heat level setting. After the unit has been turned on you may select the desired heat level.
However, the feed rate heat level will not change until the unit has completed the 15 minute startup sequence. It is
recommended to burn the unit on the number #2 or #3 heat level setting for the first 30-45 minutes.
If the fire temperature has not reached proper operating temperature within the minimum cycle time (15 min.) the auger will
stop feeding, the stove will shut down and the #3 heat level setting light will blink. You will need to press and hold the
ON/OFF button for 6 seconds to start the cycle over again. If the system is set on auto start it will attempt two startups on its
own.
The draft and room air blower speed varies directly with the feed rate. The “Draft Trim” button will override the variable fan
fu/- 5 volts on all heat levels. To override, press and hold the “Draft Trim” button along with the heat level button
arrow up or heat level button arrow down, depending on desired change.
The auger feed rate on each setting is pre-programmed but may be changed if necessary. The “Auger Trim” button will
override the programmed feed rates by +/-5% on all heat levels. To override the feed rate press and hold the ‘Auger Trim’
button along with the heat level button arrow up or heat level button arrow down, depending on desired change.
NOTE: In case of a power outage or interruption lasting longer than 5 seconds, the “On/Off” button must be pushed to
re-engage the auger. If needed re-light the unit.
NOTE: If the fire is burning too fast and the fuel is being burned up too quickly, turn the air intake butterfly damper
closed a little to slow the fire down. This should be done in small 1/4” increments so that the fire doesn’t change too
quickly. You may also adjust the draft and auger trim to balance the burn rate.
NOTE: When changing the heat levels there will be a delay so the system can complete the cycle before switching to the
new heat level.
NOTE: In case of a power outage, the pressure switch has tripped, the door has been opened, the hopper door has been
left open or any power interruption lasting longer than 5 seconds, the “On/Off” button must be pushed and held for
app. 6 seconds (or until you here a click) to re-engage the auger system.
IMPORTANT: The circuit board will not function properly if the outlet is not a constant 120 volt, 60 cycle power
source. The outlet must be grounded properly and have the correct polarity. A polarity and ground tester can be
picked up at any hardware store to assure proper operation. If you are using a power generator, solar power or wind
generation make sure that you have a constant correct power source.
The unit’s electrical warranty would become void if a constant power source is not available. Also make sure that a
proper surge protector is between the unit and the power source. The circuit board will not be warranted if there is not
a surge protector installed to the unit.
It is strongly recommended that you unplug the power source during times when the unit is not being operated to
protect the unit from power surges, power spikes and drops in power. It is very common for a circuit board to work
when the unit is shut off in the spring and then won’t work in the fall. Unplugging the unit will prevent this from
happening.
Summary of Contents for Elite WIN-ACI
Page 20: ...20 MAGNUM WIN INSERT INSTALLATION...
Page 24: ...24...
Page 25: ...25 Fireplace Insert Shroud Installation Diagram...
Page 26: ...26 Thermostat wire connection Low voltage thermostat Molex Plug 24 volt thermostat hookup...
Page 40: ...40 AC MODEL WIRING DIAGRAM WARNING DISCONNECT POWER BEFORE SERVICING THIS UNIT...