9
CLEARANCES
NOTE: Clearances for the Insert models are shown on pages 21-24
CONVENTIONAL CLEARANCES
A…SIDEWALL
3 In. (75 mm)
B…BACK WALL
3 In. (75 mm)…… (VERTICAL VENTING INSTALLATION REQUIRES A MIN. 3”
CLEARANCE FROM COMBUSTIBLES TO VENT PIPE).
C…CORNER WALL
3 In (75 mm)……. (VERTICAL VENTING INSTALLATION REQUIRES A MIN. 3”
CLEARANCE FROM COMBUSTIBLES TO VENT PIPE).
D…VENT PIPE TO WALL
3 In (75 mm)…….. (MAINTAIN 3” CLEARANCE FOR ALL INSTALLATIONS)
E…FLOOR PROTECTION FRONT 6 In (150 mm)
F…FLOOR PROTECTION SIDES
6 In (150 mm)
Floor protection must be 3/8” minimum thickness non-combustible material or equivalent extending beneath heater and to the
front/side/rear as indicated.
CHIMNEY AND CONNECTOR: 3” LISTED PELLET VENT ONLY
NOTE: REGARDLESS OF STOVE CLEARANCE, VENT PIPE MUST ALWAYS HAVE A 3” INCH CLEARANCE.
ALCOVE CLEARANCES
MIN. ALCOVE WIDTH
27 In. (694 mm)
MIN. ALCOVE HEIGHT
47 In. (1194 mm)
MAX. ALCOVE DEPTH
36 In. (914 mm)
WARNING: THE MINIMUM CLEARANCES LISTED ABOVE ARE BASED ON 3” PL LISTED PELLET VENT
PIPE. IF YOUR APPIANCE IS NOT PROPERLY INSTALLED A HOUSE FIRE MAY RESULT. PLEASE
FOLLOW THE PIPE MANUFACTURERS INSTRUCTIONS AND LOCAL BUILDING CODES FOR THE
CLEARANCE TO COMBUSTIBLES REQUIRED FOR THE INSTALLATION OF THE VENT PIPE BEING USED.