7.Take 220V contactor and connect the each junction one by one. Besides, exchange the connecting wire from 110V
contactor to 220V contactor.
110V
110V
220V
220V
220V
220V
110V
220V
6.Remove the retainer and pull the contactor out of the machine.
110V CHANGED TO 220V
MAGNUM INDUSTRIAL MI-91500 DELUXE 14” BAND SAW
5.Dismantle the connecting wire on 110V 15A temperature controlled switch and connect on 220V 7A temperature controlled
switch; then install at reverse direction by the above steps.
110V 15A temperature
controlled switch
220V 7A temperature
controlled switch
220V 7A temperature
controlled switch
Summary of Contents for MI-91500