15
57-642 ECLIPSE Model 705 Guided Wave Radar Transmitter for Hygienic Industries
2.6.3 Transmitter Display and Keypad
The ECLIPSE transmitter has an optional liquid crystal dis-
play (LCD) capable of showing two lines of 8 characters
each. Transmitter measurements and configuration menu
screens are shown on the LCD.
The transmitter default display is the measurement screen.
It cycles every five seconds to display STATUS, LEVEL,
%OUTPUT, and LOOP information (LEVEL,
%OUTPUT, and STATUS for Fieldbus version). The
transmitter defaults to this display after five minutes with-
out a keystroke.
The keypad has three arrows used to scroll through the dis-
plays and to calibrate the transmitter. The Up and Down
Arrow ( ) keys and the Enter ( ) key.
Function in
Function in
Arrows
Display Mode
Configuration Mode
Up and Down Moves forward and backward
Increases or decreases the
in the configuration program
value displayed or moves to
from one display to another.
another choice.
NOTE: Hold arrow key for
rapid scrolling.
Enter
Enters the configuration mode
Accepts a value and moves
(noted by an exclamation point to the next step of the
as the last character in the top
configuration program.
display line).
2.6.4 Password Protection (Default = 0)
The ECLIPSE transmitter is password protected to restrict
access to certain portions of the menu structure that affect
the operation of the system. When the proper password is
entered, an exclamation point (!) appears as the last charac-
ter of the first line of the display. The password can be
changed to any numerical value up to 255. The password
is required whenever configuration values are changed.
The default user password installed in the transmitter at
the factory is 0. The last step in the configuration menu
provides the option to enter a new password. With a pass-
word of 0, the transmitter is no longer password protected
and any value in the menu can be adjusted without enter-
ing a confirming password, except diagnostic values.
NOTE: If the password is not known, the menu item New Password
displays an encrypted value representing the present pass-
word. Call the factory with this encrypted value to determine
the present password.
➪
➪
➪
Enter
Down
Up
➪
➪
➪