Operation Instructions
MBE35_50 OPERATION MANUAL 2005_10
14
☞
4.0 Controller
4.1 General
The ECOLINE controller has been specially designed for use with MBE 35and MBE
50 barrier gates. It cannot be used with any other barrier type.
This controller enables the barrier to be operated manually or automatically. There are
11 standard functions to be selected for operating the barriers. These functions cover
all standard applications.
The controller has 6 Inputs and 4 outputs. The operating mode and special
functionality can be adjusted using the rotary switch and the DIP switch. The
controller also comes with a manual reset button to reset the controller after any
changes were made.
The connection of additional safety equipment for pedestrians is possible.
Besides the standard operating modes several special functions are additionally
integrated. These enable the operation of traffic lights. The storage of opening pulses
(Vent signal count) makes access control possible. After power failure, there are three
possibilities to restart the barrier: Manual reset, signal reset or automatically. For
safety reasons the manual reset function is factory-set. This means the barrier
remains open until the reset button at the control unit is pressed. The electrical
connections are made on labeled terminal blocks. The motor is driven by a TRIAC
output stage.
Selection of the operating mode and the special functions are done by a rotary
selector switch and DIP-Switches.
For the power supply of optional external devices, for example induction loop
detectors, 24VDC/0.5A is supplied.
The controller has 6 Inputs and 4 outputs. The operating mode and special
functionality can be adjusted using the rotary switch and the DIPswitch. The controller
also comes with a manual reset button to reset the controller after any changes were
made.
Note: