Operation Instructions 

MBE35_50 OPERATION MANUAL 2005_10 

 - 

25 

-

 

When the gate is closing and the pedestrian safety input IN4 detects a person the 
barrier returns to the fully up position. After IN4 is cleared, the gate will remain in the 
open position for an additional 5 sec. until the gate closes (Note: It will only close if 
the closing contact on IN3 is still made). The pedestrian safety input on IN4 must be 
disabled in the down position with a limit switch (optional, not included in standard 
package). 
 
  
When the gate is closing and the vehicle safety input IN5 receives an input the 
barrier returns to the fully open position. As soon as the safety zone is cleared, the 
barrier closes immediately, as long as the closing contact on IN3 is made. When the 
barrier is closing and has already passed the switch point of the down limit switch, 
the safety feature is disabled and the gate will continue to close regardless if the 
safety device detects an object. Ex factory, the limit switch is adjusted to disable the 
safety/closing device on IN5 15º before it reaches the fully closed position. 

 
 
 

4.6.3 Operating  Mode  3 

Pulse control using one input (IN1), Static

 

Each input (pulse) on IN1 results in a change of direction (up/down). When the 
controller is setup for signal reset (see 

chapter 4.5

 DIP switch setting 1-2) the 

controller can be reset with a momentary input on IN3 or a vehicle passing the 
safety closing device connected on IN5. 
 

 
 

 
 
 
 

 

 
 
 
 
 
 
 
 
 
 

 

Every pulse signal (min. 200ms in length) on input IN1 will change the direction of 
the barrier. For example: First pulse IN1 opens barrier, Second pulse IN1 closes 
barrier, and third pulse IN1 opens barrier ….etc.  
The barrier closes after a controller reset. For the different options on how to reset 
the controller, please see 

chapter 4.5

 DIPswitch 1-2.  

In operating mode 3, the only function of IN3 is to reset the controller at start up. 
During normal operation in mode 3 IN3 has no function. 

 

When the gate is closing and the pedestrian safety input IN4 detects a person the 
barrier returns to the fully up position. After IN4 is cleared, the gate will remain in the 

1 2 3 4 5 6 24VDC

INPUT

 

IN1 = open/close barrier 
IN2 = not used 
IN3 = Signal reset 
IN4 = Pedestrian safety input 
IN5 = Vehicle safety device 
IN6 = Down limit switch 
disabling of vehicle safety 
device (IN5) when gate is in 
down position.   
 
All inputs require a potential 
free (dry) contact.  

Summary of Contents for MAGSTOP MBE35

Page 1: ...Operation Instructions MBE35_50 OPERATION MANUAL 2005_10 1 Operating Instructions MAGSTOP Traffic Barrier MBE35 50 Version 2005_10...

Page 2: ...TS 16 4 3 CONTROLLER OUTPUTS 18 4 4 OPERATING MODES AND ADDITIONAL FUNCTIONS 19 4 5 DIP SWITCH SETTINGS 20 4 6 OPERATING MODES 23 4 6 1 OPERATING MODE 1 23 4 6 2 OPERATING MODE 2 24 4 6 3 OPERATING MO...

Page 3: ...E 51 6 3 STANDARD CONFIGURATION 51 7 0 BARRIER ARM SUPPORT 52 7 1 PENDULUM SUPPORT 52 7 2 SUPPORT POST 52 8 0 ARTICULATED GATE ARMS 54 9 0 TECHNICAL DATA 55 9 1 MAGSTOP BARRIERS 55 9 2 CONTROLLER ERRO...

Page 4: ...ion Caution This symbol is used in this manual to designate those actions or states which represent a potential hazard to petestrian personal property and equipment Please read these instructions very...

Page 5: ...ed to control vehicular see pictogram below access and exits to car parks car parking garages access control applications and highways The MAGTRONIC control units have been specially designed for cont...

Page 6: ...or require having pedestrian entrances on opposite side of vehicle entrance and exit IMPORTANT It is A MUST to have pedestrian sidewalks installed parallel to entrance and exit lanes or to have pedes...

Page 7: ...of the barrier boom must be directly observable by the person operating the barrier While the barrier boom is in motion no pedestrian and no vehicle shall be in the immediate vicinity of the barrier T...

Page 8: ...omponents but excludes parts subject to wear and tear for a period of two years from the date of first use or for a maximum of three years from the date on which the system was delivered provided that...

Page 9: ...induction loop lead wire dia 3 Conduit for power cables dia 1 4 Conduit for control cables dia 5 Concrete foundation Conduit pipes with different diameters for low and high voltage cables as per Elect...

Page 10: ...s 2 1 Mounting the housing to the ground To mount the barrier gate on the concrete surface follow the instructions below 1 Carefully remove the gate from its shipping crate 2 Open the barrier door 3 P...

Page 11: ...tions Make sure that the bolts stand up at least 2 inches above the concrete surface 9 Place the gate on top of the previous marked area 10 Using the supplied U channel in accessory box secure the gat...

Page 12: ...certain that the main circuit breaker is switched OFF Connect all electrical wiring exactly as directed in the Connection Diagram 12 Attach the gate arm to the flange using the boom attachment kit in...

Page 13: ...rm length exceeding 12 ft it is not recommended to use any material other then the provided 8mm steel hex nuts Due to age deterioration UV radiation the plastic nuts must be replaced annually 3 0 Oper...

Page 14: ...ctions are additionally integrated These enable the operation of traffic lights The storage of opening pulses Vent signal count makes access control possible After power failure there are three possib...

Page 15: ...Instructions MBE35_50 OPERATION MANUAL 2005_10 15 Each in and output has a red LED Indicator light to display which in or output is currently activated Light on in output active Light off in output n...

Page 16: ...opening loop The open hold time will not be set in any of the modes IN 3 Gate close input Requires a potential free a normally open contact This input will close the gate as long as none of the safety...

Page 17: ...gate is in the down position 3 If the controller is setup for signal reset see chapter 4 5 DIP Switch 2 it uses the limit switch feedback to determine in what position the gate is when the main power...

Page 18: ...Pswitch 6 in on position 500ms pulse signal when the controller received in input on IN1 gate open K3 Depending on DIP switch 7 settings DIPswitch 7 in off position This output is used to turn warning...

Page 19: ...11 operating modes can be set by turning the rotary switch to the desired position see chapter 4 6 The additional function can be set by setting the DIP Switches to a certain position see chapter 4 5...

Page 20: ...set The gate will close immediately after the power is restored as long there is no vehicle or pedestrian if IN4 is used in the detection zone ATTENTION If the power was restored while a vehicle was o...

Page 21: ...not close until the timer is elapsed 5 OFF Relay K1 active when gate starts to open Indication of motor drive direction Relay cycles on off when a gate failure occurred 5 ON Relay K1 active when gate...

Page 22: ...is waiting for a manual or signal reset 3 Input IN 4 was activated contact open for longer than 3 minutes In case the photo sensor is dirty or damaged 4 Input IN5 was activated contact open for longe...

Page 23: ...rier after the power to the barrier is turned on please see chapter 4 5 DIPswitch setting 1 2 When the gate is closing and the pedestrian safety input IN4 detects a person the barrier returns to the f...

Page 24: ...The barrier will open or remain open after power up and reset when the barrier close input IN3 is not made The barrier only closes if the closing signal on IN3 is maintained until the barrier reaches...

Page 25: ...osition 4 6 3Operating Mode 3 Pulse control using one input IN1 Static Each input pulse on IN1 results in a change of direction up down When the controller is setup for signal reset see chapter 4 5 DI...

Page 26: ...d IN5 are not active After that a pulse or maintained contact on IN1 opens the barrier and a pulse or maintained contact on IN3 closes the barrier The barrier open input IN1 has a higher priority than...

Page 27: ...4 5 DIPswitch 1 and 2 as long as the safety inputs IN4 and IN5 are not active After that a pulse or maintained contact on IN1 or a pulse on IN2 opens the barrier The barrier closes after a pulse or m...

Page 28: ...vice detects an object Ex factory the limit switch is adjusted to disable the safety closing device on IN5 15 before it reaches the fully closed position Directional Logic Mode 5 has built in directio...

Page 29: ...the opening loop detector detects the vehicle and remains open as long as the vehicle remains on the opening loop i e as long as the detector detects the vehicle The gate closes immediately after the...

Page 30: ...gate opens 3 Vehicle activates both loops at the same time Gate is up 4 Vehicle leaves opening loop B while still on loop A Gate is up 5 Vehicle leaves loop A Gate closes LO O P B LO O P A Travel Dir...

Page 31: ...N3 or passing the safety closing loop IN5 The barrier open input IN1 has a higher priority than the opening loop input IN2 or the closing input IN3 therefore the barrier will open when a close input o...

Page 32: ...e the traffic lane in both directions IMPORTANT It is imperative to install the two inductive loops only so far apart that at time of entry or exit both loops are detected simultaneously Both detector...

Page 33: ...long as the vehicle remains on the opening loop i e as long as the detector detects the vehicle The gate closes immediately after the vehicle passed both loops Logic Loop B BA A gate closes See drawin...

Page 34: ...34 3 Vehicle activates both loops at the same time Gate is up 4 Vehicle leaves opening loop B while still on loop A Gate is up 5 Vehicle leaves loop A Gate closes LOOP B LOOP A Travel Direction LOOP...

Page 35: ...e safety closing device which decrements the stored count to zero 0 or the reset time elapsed In other words if five 5 cars sent an opening command to IN1 five 5 cars have to pass through the safety c...

Page 36: ...ry time a vehicle passes through the safety closing device it decrements the count by one The controller automatically sets the reset timer to 30sec max The reset timer is the timer that closes the ga...

Page 37: ...nt and IN5 decrements the count If a vehicle enters the facility using IN1 it increments the count by one 1 if this vehicle passes through the safety closing device connected to IN5 it decrements the...

Page 38: ...ens as soon as the opening loop detector detects the vehicle and remains open as long as the vehicle remains on the opening loop i e as long as the detector detects the vehicle The gate closes immedia...

Page 39: ...count gate opens 3 Vehicle activates both loops at the same time Gate is up 4 Vehicle leaves opening loop B while still on loop A Gate is up 5 Vehicle leaves loop A Gate closes LO O P B LO O P A Trav...

Page 40: ...opening command to IN1 five 5 cars have to pass through the safety closing device for the barrier to close In Mode B the gate will not time out to close If for any reason the timer has to be reset to...

Page 41: ...y using IN1 it increments the count by one 1 if this vehicle passes through the safety closing device connected to IN5 it decrements the count by one 1 If the same traffic lane is used in both directi...

Page 42: ...ens as soon as the opening loop detector detects the vehicle and remains open as long as the vehicle remains on the opening loop i e as long as the detector detects the vehicle The gate closes immedia...

Page 43: ...count gate opens 3 Vehicle activates both loops at the same time Gate is up 4 Vehicle leaves opening loop B while still on loop A Gate is up 5 Vehicle leaves loop A Gate closes LO O P B LO O P A Trav...

Page 44: ...oller system self adjusts to the connected loop Many factors determine loop inductance including wire size wire length the number of turns lead length and insulation Changes in loop inductance due to...

Page 45: ...the ends together will quickly disprove the misconception The single wire forming a shorted turn provides a current path for the magnetic field thus causing a loading effect similar to that of a vehi...

Page 46: ...urns required ALWAYS USE AT LEAST 2 TURNS In addition to the above result the inductivity of the wires used in the loop must be added Depending on the used wire it is between 1 1 5 H per every three 3...

Page 47: ...they meet our requirements explained in this manual Please refer to loop manufacturers Installation Instructions 5 4 2 Self Made Loops A loop can be manufactured from a single AWG 14 18 stranded XLPE...

Page 48: ...eads of multiple loops should not use the same cable or conduit If it is not possible to have separate conduits for multiple loop leads a shielded twisted pair wire must be used for each loop The lead...

Page 49: ...ar and the elements The top wire should be a minimum of 1 inch below the road surface Note Nonconductive materials such as concrete and asphalt will not influence the loop fields Installing the loop o...

Page 50: ...ioning of the loop cannot be guaranteed The loop and loop leads must not be installed near to any underground high voltage cables The distance between loops and barrier housings or barrier arms should...

Page 51: ...f the barrier 6 2 Setting up the controller Note Ex factory the barrier comes in operating mode 5 and all DIP Switches in the OFF position Please read Chapter 4 0 Controller for controller setup 6 3 S...

Page 52: ...ews located on the center ring of the rod and turn the bottom cylinder clockwise to lengthen or counter clockwise to shorten the support When the gate arm is in the down position the distance between...

Page 53: ...L 2005_10 53 Note The height of the support post can be adjusted to compensate differences in height between the barrier and the support post foundation Cradle w ith foam pad Adjustm ent Loosen the tw...

Page 54: ...h our articulated gate arms up to 12 ft in length The drawings below show how to attach the articulated arms to the barrier Note If the barrier was ordered with the articulated arm no additional drill...

Page 55: ...Maintenance The MBE35 50 series barrier gates are designed for a long lifetime with only a minimum of maintenance required To guarantee the greatest available equipment uptime and maximize the lifetim...

Page 56: ...and tight Perform this inspection every six months 10 4 Checking the Loop Detectors and Loop Wires Check the frequencies of the loops every six months The loop wires should be replaced approximately...

Page 57: ...d Gate Model Gate Serial Number Date Of Installation Minimum Date Date Date Date Date Replace Rubber End Stop Every year Inspect Cabinet Every 6 months Inspect barrier arm Every 6 months Check Loop Fr...

Page 58: ...L 32955 Phone 321 635 8585 Fax 321 635 9449 E Mail info magnetic usa com Web http www ac magnetic com For Sales and Service Contact Your Local Magnetic Automation Corp Distributor 2001 Magnetic Automa...