Flex 8RS System Instruction Manual
December 2012
14 of 36
4.1.2 Push Button Functions – Setup
WARNING
THE TRANSMITTERS ARE UNIQUE AND FACTORY PRESET. DO NOT CHANGE THE TRANSMITTER SETTINGS
UNLESS YOU ARE REPLACING AN EXISTING TRANSMITTER. CHANGING THE SETTINGS COULD MAKE IT
COMMON WITH ANOTHER TRANSMITTER, WHICH COULD MOVE OTHER EQUIPMENT. WRONG TRANSMITTER
SETTINGS MAY CAUSE EQUIPMENT TO OPERATE IMPROPERLY. FAILURE TO FOLLOW THIS WARNING COULD
RESULT IN SERIOUS INJURY OR DEATH, AND DAMAGE TO EQUIPMENT.
NOTE: All settings are pre-set at the factory. The following information is to be used for setting up
replacement transmitters only.
NOTE: For all system types, the transmitter function dipswitch 7 selects operation of the system in
interlock and non-interlock modes
.
When interlock mode is selected (dipswitch 7 is on/up), only 1 receiver can be selected at a time.
When non-interlock mode is selected (dipswitch 7 is off/down), all receivers can be selected at the same
time.
4.1.2.1 Type “B” Transmitter Setup and Configuration
Push Button
RS System
TYPE B
Setting
A/B Receiver Select
with Bridge Receiver
ON
CTS
1 2 3 4 5 6 7 8
FUNCTION DIP_SW
TYPE B
A,B,C,D interlock/non-interlock
Transmitter
S/N: XXXXXX
TYPE:01
A
B
C
D
B
A
Receiver A
Receiver B
S/N:XXXXXX
TYPE:01
S/N:XXXXXX
TYPE:02
Bridge RX
S/N:XXXXXX
TYPE:00
JP4: Shorted
JP5: Shorted
*UP (1): interlock, Down (0): non-Interlock
*When receiver is selected,
relays respond to TX buttons
1, 2, 3 and 4
Refer to Relay Chart #1
*When receiver is selected,
relays respond to TX buttons
1, 2, 3 and 4
Refer to Relay Chart #1
*Receiver is always selected.
Relays respond to TX buttons
5 and 6
Refer to Relay Chart #2