Final torque during soft-stopping a pump motor
1. While decelerating, the check valve may close
before Deceleration Time has elapsed, thus,
allowing current to flow through stator winding
causing unnecessary heat. Select Final Torque
sensitivity to 1, and stop the pump, confirm that
current stopped flowing through the motor
shortly after the check valve closed.
2. If current still flows more than 3-5 seconds
after check valve closure, increase Final Torque
up to 10 if necessary, to stop current flow earlier.
Summary of Contents for 188-10130
Page 7: ...c h a p t e r 1 Introduction...
Page 8: ...This page intentionally left blank...
Page 11: ...c h a p t e r 2 Installation...
Page 12: ...This page intentionally left blank...
Page 15: ...c h a p t e r 3 RVS DX Terminals and Wiring...
Page 16: ...This page intentionally left blank...
Page 18: ...RVS DX Digital Soft Starter Instruction Manual 04 01 04 3 4 Typical Wiring Diagram...
Page 21: ...c h a p t e r 4 Control Layout...
Page 22: ...This page intentionally left blank...
Page 27: ...c h a p t e r 5 Features...
Page 28: ...This page intentionally left blank...
Page 37: ...c h a p t e r 6 Parameters...
Page 38: ...This page intentionally left blank...
Page 46: ...c h a p t e r 7 Start Up Procedure...
Page 47: ...This page intentionally left blank...
Page 52: ...C h a p t e r 8 Troubleshooting...
Page 53: ...This page intentionally left blank...
Page 56: ...a p p e n d i x A Technical Data Specifications...
Page 57: ...This page intentionally left blank...
Page 60: ...a p p e n d i x B Dimensional Drawings...
Page 61: ...This page intentionally left blank...
Page 64: ...RVS DX Digital Soft Starter Instruction Manual 4 01 04 B 5 Protected Chassis RVS DX 210 310A...
Page 65: ...a p p e n d i x C Fuse Selection Table...