![Magnetek 188-10130 Instruction Manual Download Page 14](http://html1.mh-extra.com/html/magnetek/188-10130/188-10130_instruction-manual_3606638014.webp)
RVS-DX, Digital Soft Starter Instruction Manual—04/01/04
2-4
Built in Bypass After Acceleration
The bypass after acceleration allows the RVS-DX to control the motor during starting and stopping
for smooth, step-less acceleration and deceleration. However, once up to full voltage the RVS-DX is
bypassed to reduce the watt loss.
The RVS-DX incorporates internal bypass relays allowing current flow through the SCR’s only
during the soft start process. At the end of the soft start, the built-in relays bypass the SCR’s and
carry current to the motor. Upon stop signal, or in case of fault, all three bypass relays will open and
stop the motor. When the decel time is set to allow soft stopping, upon stop command, the bypass
relays will open immediately and the current will flow through the SCR’s. The voltage will then be
reduced slowly and smoothly to zero.
RVS-DX units rated 31-310 amps have built-in bypass.
C/T
C/T
M
x 3
Summary of Contents for 188-10130
Page 7: ...c h a p t e r 1 Introduction...
Page 8: ...This page intentionally left blank...
Page 11: ...c h a p t e r 2 Installation...
Page 12: ...This page intentionally left blank...
Page 15: ...c h a p t e r 3 RVS DX Terminals and Wiring...
Page 16: ...This page intentionally left blank...
Page 18: ...RVS DX Digital Soft Starter Instruction Manual 04 01 04 3 4 Typical Wiring Diagram...
Page 21: ...c h a p t e r 4 Control Layout...
Page 22: ...This page intentionally left blank...
Page 27: ...c h a p t e r 5 Features...
Page 28: ...This page intentionally left blank...
Page 37: ...c h a p t e r 6 Parameters...
Page 38: ...This page intentionally left blank...
Page 46: ...c h a p t e r 7 Start Up Procedure...
Page 47: ...This page intentionally left blank...
Page 52: ...C h a p t e r 8 Troubleshooting...
Page 53: ...This page intentionally left blank...
Page 56: ...a p p e n d i x A Technical Data Specifications...
Page 57: ...This page intentionally left blank...
Page 60: ...a p p e n d i x B Dimensional Drawings...
Page 61: ...This page intentionally left blank...
Page 64: ...RVS DX Digital Soft Starter Instruction Manual 4 01 04 B 5 Protected Chassis RVS DX 210 310A...
Page 65: ...a p p e n d i x C Fuse Selection Table...