Transporting the control cabinet
Only necessary if the control cabinet is not fixed to
the machine.
Procedure:
1. Check eyelets are securely fixed in place.
2. Attach rope harness for crane transport to the eye-
lets on top of the cabinet.
3. Lift the control cabinet carefully a small distance off
the ground. Pay attention to the centre of gravity; if
necessary, adjust the ropes so the cabinet hangs
level on the crane.
4. Transport the machine to the installation site as
close to the ground as possible.
5. Lower the machine slowly and carefully into place.
6. INSTALLATION
6.1 SET UP THE MACHINE
CAUTION:
Insufficient ventilation of
controls, motors and transformers can
lead to overheating. Set up the ma-
chine in such a way to ensure free air
flow through the ventilation grilles.
Prerequisites:
• Take the exact installation positions of the individual
components from the floor plan.
• Install the machine on a level surface in a closed,
dry room.
Procedure:
1. Set the machine down at its final location.
2. Mark the positions of the drilled holes through the
holes in the screw-on plates on the floor.
3. Move the machine slightly to the side.
4. Drill holes in the floor and insert suitable dowels.
5. Move the machine back to its final position.
6. Insert screws through the mounting plates into the
dowels in the floor
7. Tighten the screws.
6.2 CONNECT THE POWER SUPPLY
DANGER: High voltages can cause
lethal electric shock and burns.
Electric connections should only be created
:
• in accordance with the wiring diagram and the infor-
mation provided on the type plate
• in compliance with applicable standards in your
country.
• by a qualified electrician.
Power supply
Observe the information about the power supply on
the machine's type plate and in the circuit diagram.
When connecting the power supply:
• Use only delay fuses
• Use cables of appropriate length and suitable for
the power supply conditions.
The cable entry point is located on the underside of
the control cabinet.
16