2.3 Mains Plug Connection
2.4 Connection to Mains
• No plug has been connected to the mains cable since there may
different types of outlets available in plants, construction sites and
workshops. A suitable plug must be connected by a qualified
electrician.
• Make sure that the grounding cable is present.
• After connecting the plug to the cable, do not attach it to the outlet
at this stage.
• Support should be received from authorized persons (qualified electricians, etc.). Check the phase voltage
before connecting the machine to the mains. The plug must be plugged to the outlet once it is observed to be
correct.
• Turn the coarse on/off switch to position “1” to start the machine. Make sure that the indicators and leds on the
control panel are lit and the cooling fan is operating.
• Turn the machine off by turning the on / off switch back to the “0” position.
For your safety, never use the mains cable of the machine without a plug.
When plugging the power plug into the outlet, make sure that the on/off switch is set to “0”.
2.5 Connections for TIG Welding
2.5.1 Torch Connections
• Start the machine with the on/off switch and check whether the LEDs are on and the cooling fan is working.
• Insert the TIG torch’s plug into the negative pole welding socket and tighten it by turning to the right. Attach the
torch trigger connector that came with the machine to the trigger control cables of the torch. Then connect the
connector to the trigger control socket.
• Connect the gas hose of the torch to the gas outlet.
• In water-cooled models, connect the cold “blue” hose of the torch to the cold water outlet on the machine, and
the hot “red” hose to the hot water inlet on the machine.
Check for the correct mains voltage before connecting the machine to the mains.
When plugging the power plug into the outlet, make sure that the power switch is set to “0” in
the turned-off position.
Tungsten Electrode
Diameter (mm)
Recommended TIG
Welding Current
1.6
2.0
2.4
30-130
45-180
70-240
Installation
Figure 2 : Mains Plug Connection