INSTALLATION

2.1 Delivery Control

2.2 Installation and Operation Recommendations

Make sure that all the materials you have ordered have been received. If any material is missing or damaged, 

contact your place of purchase immediately.

Scope of supply;

• Welding machine and connected mains cable 

•   Warranty certificate

•  Workpiece clamp and cable     

 

•   Torch

• User manual

In case of a damaged delivery, record a report, take a picture of the damage and report to the transport

company together with a photocopy of the delivery note. If the problem persists, contact the customer service.

•  For a better performance, place the machine at least 30 cm away from the surrounding objects. Pay attention 

  to overheating, dust and moisture near the machine.

•  Do not operate the machine under direct sunlight. If the ambient temperature exceeds 40°C, operate the 

  machine at a lower current or a lower duty cycle.

•  Avoid welding outdoors in windy and rainy weather circumstances. If welding is necessary in such cases, 

  protect the welding area and the welding machine with a curtain and canopy. If you weld indoors, use a

  suitable fume extraction system. Use breathing apparatus if there is a risk of inhaling welding fumes and gas 

  in confined spaces.

•  When positioning the machine, make sure that materials such as walls, curtains, panels, etc. do not impede 

  easy access to the controls and connections of the machine.

•  Observe the duty cycle rates specified on the product label. Exceeding duty cycle rates can damage the

  machine and this may invalidate the warranty.

•  Use the fuse that is compliant with your system.

•  Secure the ground cable as close as possible to the welding area.

•  Do not allow the welding current to pass through equipment other than the welding cables.

•  The welding cables and the mains cable must not be wrapped in the machine housing during operation.

•  When the gas cylinder is placed on the machine, immediately fasten the chain to secure the gas cylinder. If you 

  do not place the gas cylinder on the machine, fasten it to the wall with a chain

Symbols and their meanings on the device

Welding    may    be    dangerous. Proper working conditions should be ensured and necessary

precautions should be taken. Specialists are responsible for the machine and have to be equipped with the 

necessary equipment and those who are not relevant should be kept away from the welding area.

This device is not compatible with IEC 61000-3-12. If it is desired to connect to the low voltage mains used 

in homes, it is essential that the installer or the person who will operate the machine to make the electrical 

connection has information on the machine’s connectivity. In this case the responsibility will be assumed 

by the person who will perform the installation or by the operator.

The safety symbols and warning notes on the device and in the operating instructions must be observed 

and the labels must not be removed.

Grids are intended for ventilation. The openings should not be covered in order to provide good cooling and 

no foreign objects should be inserted.

Installation

Summary of Contents for ID 300T DC

Page 1: ...ID 250T DC ID 300T DC 90 444 93 53 magmaweld com info magmaweld com 90 538 927 12 62 USER MANUAL...

Page 2: ...kine Sanayi ve Ticaret A Magma Mekatronik may modify the information and the images without any prior notice T m haklar sakl d r Magma Mekatronik Makine Sanayi ve Ticaret A nin yaz l izni olmaks z n b...

Page 3: ...TR EN DC WELDING INVERTER DC KAYNAK NVERT R 3 ID 250T DC ID 300T DC...

Page 4: ...and Operation Recommendations Mains Plug Connection Connection to Mains Connections for TIG Welding Torch Connections Gas Connections Trigger and Pedal System Socket Connections Grounding Clamps Conn...

Page 5: ...injuries may occur Make certain that the installation procedures comply with national electrical standards and other relevant regulations and ensure that the machine is installed by authorized persons...

Page 6: ...the above precautions If the gas tanks are grouped in a separate zone ensure that they are well ventilated keep the main valves closed when gas cylinders are not in use pay attention to possible gas...

Page 7: ...ions you will perform in such places Do not weld in tanks and pipes which might have previously contained substances that may cause explosions fires or other reactions Welding cutting equipment heats...

Page 8: ...free areas To prevent gas cylinders from tipping over on machines with a gas platform suitable for the tanks fix the tanks on to the platform in stationary usage applications fix them to the wall with...

Page 9: ...pliance must be carried out All covers on the body of the machine must be closed and or locked when the device is in use Any changes other than the standard settings without the written approval of th...

Page 10: ...ning materials tape cable ties etc The operator s body and head should be kept as far away from the welding cutting machine and cables as possible Welding cutting and electric cables should not be wra...

Page 11: ...of thin metal sheets except aluminum for MMA welding of all kinds of stick electrodes up to 5 mm Enhanced professional TIG controls such as HF start Touch Lift Pre Gas Up Slope Pulse Down Slope Post G...

Page 12: ...s of the 10 minutes period zone 1 However the following 4 minutes should be kept idle for the machine cool down zone 2 Duty Cycle Temperature C 6 min 6 min 6 min 4 min 4 min 4 min Time min Duty Cycle...

Page 13: ...oled TIG Torch Gas Regulator Argon Water Cooling Unit CST 60i TIG Accessory Set Air Cooled Torch Regulator Foot Pedal On Off Water Cooled TIG Accessory Set Torch Regulator Foot Pedal Current Adjustabl...

Page 14: ...hine Observe the duty cycle rates specified on the product label Exceeding duty cycle rates can damage the machine and this may invalidate the warranty Use the fuse that is compliant with your system...

Page 15: ...ety never use the mains cable of the machine without a plug When plugging the power plug into the outlet make sure that the on off switch is set to 0 2 5 Connections for TIG Welding 2 5 1 Torch Connec...

Page 16: ...inlet at the rear of the machine and turn on the gas cylinder valve Adjust the flow rate with the flow regulating valve e Make sure the connections are free of leakages 2 5 2 Gas Connections a c b d e...

Page 17: ...he grounding pliers b to the workpiece as close as possible to the welding area The ceramic gas nozzle 5 and the tungsten electrode 1 must be selected according to the operating current and the shape...

Page 18: ...e electrode manufacturer To improve the welding quality firmly connect the grounding pliers b to the workpiece as close as possible to the welding area 2 6 Connections for MMA Welding Check for the co...

Page 19: ...no further action is required for recording In addition while still in TIG modes it allows to switch to the cooling time setting when pressed for 3 seconds Digital Program Display Shows the program n...

Page 20: ...one of the rutile basic cellulosic electrode modes When the rutile electrode is selected led 10 lights up When the basic electrode is selected led 11 lights up When cellulosic electrode is selected le...

Reviews: