Page 5
2. U
SER
I
NSTRUCTIONS
2.1. Lighting the Pilot
1. Ensure that the Fan switch (
Figure 3
) is
in the OFF position then switch on the
mains electrical supply to the appliance.
2. Switch the fan ON – you should hear the
fan start and a few seconds later, the
green neon will illuminate. This neon is
located below the fire.
3. Ensure that the arrow on the control
knob is pointing towards the OFF
position as shown in
Figure 4
. Press in
the knob and slowly turn anti-clockwise
until a click is heard. The spark should
now light the pilot. On first lighting, it
may require several attempts to allow the
pilot light to be purged of air.
4. The pilot can be viewed at the front
centre of the fire.
5. Once the pilot flame is established, hold
the control knob in for approximately 10-
20 seconds and release. The pilot
should now remain alight. Repeat the
procedure if necessary.
6. The arrow should now be pointing to the
PILOT position as shown in
Figure 5
.
7. If the spark unit fails to light the pilot, the
appliance may be lit manually by
applying a lighted match or taper to the
pilot jet and following the above
procedure.
NOTE:
No attempt should be
made to relight the fire for at
least 3 minutes after the pilot
flame has been extinguished
either intentionally or
unintentionally.
I
O
Fan Switch
On
Off
Gas on
indication
Figure 3 - Duo Power Fan Control (Standard)
Figure 4 - Off Position
Figure 5 - Ignition Position