Page 22
3.4. Ventilation
For models with heat inputs not exceeding 6.9kW, normal adventitious ventilation is usually
sufficient to satisfy the ventilation requirements of these appliances. In GB reference should
be made to BS 5871 Part 3, and in IE reference should be made to the current edition of
I.S.813 which makes clear the conditions that must be met to demonstrate that sufficient
ventilation is available.
If provided, any purpose provided ventilation must be checked periodically to ensure it is free
from obstructions.
When fitting the fire in Northern Ireland (NI), purpose provided ventilation must be provided in
accordance with the rules in force.
In other EC countries equivalent rules in force must be used.
3.5. Technical Data
Natural Gas Models
LPG Gas Models
Nominal maximum heat input
6.9 kW (gross)
6.5 kW (gross)
Setting pressure (Cold)
6.5 mbar ±0.2 mbar
34.0 mbar ±1.0 mbar
Minimum heat Input
4.0 kW (gross)
3.0 kW (gross)
Minimum setting pressure
2.1 mbar ±0.2 mbar
7.0 mbar ±0.5 mbar
Gas
G20 (Natural Gas)
G31 (LPG)
Injector Size
No. 100
No. 190
Gas inlet connection
8mm
8mm
Control valve
BM
BM
Pilot
SIT OxyPilot 9039
SIT OxyPilot 9223
Air Pressure Switch
LGW3 A1 0.35 FV
LGW3 A1 0.35 FV
Control Box (Pectron)
ASS-0426G04
ASS-0426G04
Weight
10.5kg
10.5kg
Supply Voltage
230 V a.c.
230 V a.c.
Supply Frequency
50 Hz
50 Hz
Supply Fuse Rating
3 Amp
3 Amp
Protection IP20
IP20