rOuBleShOOtinG
AC power failure:
This may occur if your security system is accidentally unplugged or if there has been a main power
cut. If a full power failure occurs, please contact your electric company to find out the source of the
problem. The back-up battery will continue to run the system for approximately 6 hours.
System battery failure:
This may occur if the emergency back-up battery has been drained and needs to be replaced. If AC
power is not restored, the low battery symbol will flash indicating that the panel back-up battery is
running low. The back-up battery should be replaced once the low battery symbol appears.
Sensor failure:
This may occur if a sensor is not communicating with the panel. It is necessary for you to ensure the
House Security Code dip-switch and jumpers of the sensors are set correctly to the panel.
SECTION 6: GENERAL INFORMATION
6.1 P
rOduct
i
nfOrmatiOn
Wireless systems are reliable and tested to high standards; however, it is important to consider
that there are some limitations due to their transmitting power and range:
– Receivers may be blocked by radio signals occurring on or near operating frequencies,
regardless of the code selected.
– A receiver can only respond to one transmitted signal at a time.
– Wireless equipment should be tested regularly to determine whether there are sources
of interference and to protect against faults.
6.2 S
PecificatiOnS
6.2.1 w
ireleSS
a
larm
P
anel
Power source: ............................................................................................ AC adaptor
Back up power: ......................................................................................... 9V alkaline battery x 1
Sensor numbers: ...................................................................................... Unlimited
House Code: ............................................................................................... 4 Jumpers
Operating frequencies: .......................................................................... 433.92 MHz +/-0.5 MHz
Siren output:: .............................................................................................. 120dB (Duration-adjustable)
6.2.2 k
eychain
r
emOte
c
OntrOl
Power source: ............................................................................................ 12V alkaline battery x 1
RF working transmission frequency: ............................................... 433.92 MHz +/-0.5 MHz
House Code: ............................................................................................... 4 Jumpers
Wireless range to Wireless Alarm Panel: ...................................... < 200 feet (open area)
6.2.3 d
OOr
/w
indOw
S
enSOr
Power source: ............................................................................................ AAA alkaline battery 1.5V x 2
RF working transmission frequency: ............................................... 433.92 MHz +/-0.5 MHz
House Code: ............................................................................................... 4 Jumpers
Zone Code: Pin header: ......................................................................... 8 pin
Wireless range to Wireless Alarm Panel: ...................................... < 450 feet (open area)