215620
153
Revision A
$
%
Figure 5.59: Left Cab-Forward Platform
3.
Approach platform (A) on the left cab-forward side of the
windrower and ensure the cab door is closed.
4.
Push latch (B), and pull platform (A) toward the walking
beam until it stops and the latch engages.
$
&
%
Figure 5.60: Hydraulic Hose Management System
5.
Connect hydraulic hose management system (A) to the
windrower by securing ball joint (B) to latch support (C) on
the windrower leg.
$
%
&
'
(
)
Figure 5.61: Draper/Reel Multicoupler
6.
Retrieve draper drive and reel control multicoupler (A) from
the hydraulic hose management system.
7.
Push knob (B) on the hydraulic receptacle and pull
handle (C) fully away from the windrower.
8.
Open cover (D) and position the coupler onto the
receptacle. Align the pins in the coupler with the slots in
handle (C) and push the handle toward the windrower so
that the coupler locks onto the receptacle and knob (B)
pops out.
9.
Remove hose quick-disconnect (F) from the storage
location and connect it to the receptacle on the frame.
NOTE:
Hose quick-disconnect (F) is only present on M1240
machines configured for draper/auger headers.Hose quick-
disconnect (F) is only present on M1170 machines with the
R1 Series Hydraulic Drive kit (MD #B6845) installed.
10. Remove the cover from electrical connector (E), push the
electrical connector onto the receptacle, and secure it by
turning the collar on the electrical connector clockwise.