2.0 TECHNICAL NOTES

2.a) INPUTS AP(6) / CH(7)

the contacts to insert in these two inputs are free of tension (n.a.), aP input makes the bollard goes down, CH 

input raises the bollard.

 

INPUT AP(6)

 

It is possible to connect in parallel to this entry the following devices:

 

 

- n.a. Button

 

 

- emergency vehicles sound recognizer (sirens, police, ambulance, etc.)

 

 

- access control: telepass, reading plate, magnetic coil, ecc.

 

INPUT CH(7)

 

It is possible to connect in parallel to this input the following devices::

 

 

- n.a. Button

 

 

- Clock contact (optional hardware) (activate the  programming)

2.b) SIC1+2 SAFETY INPUT F2(4)

It has been projected for the input of any safety device (even if they are connected in series).

this input allows the reversal of running direction (only if the bollard is closing the passage).

 

Devices connectable to this input:

 

 

-magnetic detector with single/double coil.

 

 

-active modulated infrared photocells.

 

 

-Pre-calibrated pressure switch

 

 

-Positive opening limit switch installed under the sensitive head.

 

 

-any devices that respect the current laws

2.c) OUTPUTS

Specific circuit for  the ignition of an engine to improve the performances of the bollard (prevention against 

malfunctions, route defusing, ex. glued contacts).

2.d) TRAFFIC LIGHTS (16-17-18)

It has been projected to ensure a safe passage of the vehicle in the passage protected by the bollard. the green 

light will appear when the passage will be free from any obstacle.

2.e) ELECTRICAL VALVE (17-18)

It has been projected to guarantee the passage even in case of power failure.

the electrical valve will make the bollard go down up to the ground level.

2.f) OUTPUT 24V (13-14)

It is used for the power supply of the auxiliary devices (ex. Photocells).

2.g) LED LIGHTS SENSITIVE HEAD 24F (13-15)

It has been projected to supply 1 flashing bright head.

2.h) INSTALLATION

- the control board must be installed in a protected and dry place with its own protection box.

- Install a circuit breaker of type 0,03a, high sensitivity to the supply of the control board.

- make sure the supply of the control board is 230Vac ±10% 50Hz.

- For the control board, electrical motor, flashing light, traffic lights, electrical valve; use cables with wire not less 

than 1,5mm ² up to 50m of distance; for limit switches and accessories of command and safety use cables with 

wires of 1mm ². for distances of more than 50 meters use the appropriate wires with the suitable section for the 

installation. note: for applications such as lights, cameras etc. use static relays.

- The installation should be made by competent staff and in compliance with the legislation in force

- Before starting the installation, verify the integrity of the control board.

- the installation, the electrical connections and the regulations must be done to the letter.

- Packaging materials (cardboard, plastic, polystyrene, etc.) should not be dispersed into the environment.

- Do not install the control board in environment exposed to danger or disturbed by electro-magnetic fields. The 

presence of gas or flammable smokes is a great danger for safety.

- Provide on the supply network a protection for extra tensions, a switch/ disconnecting switch and/or differential 

fit for the product and with the current law.

- the constructor declines every responsibility if other devices and/or components incompatible with the product 

for integrity are installed, safety and functioning of the product.

- for reparation or substitution, only original spare parts must be used.

- the installer must give all the information related to the functioning, maintenance and use of the single parts 

and of the system in its entireness following the Directive machine (see laws en 12635, en 12453 and en 

12445).

Summary of Contents for BRAIN1

Page 1: ...Brain_1_08 190722 CONTROL BOARD BRAIN1 GBR CAREFULLY READ THE MANUAL BEFORE USE Customer Installing Company information Timbre Signature ...

Page 2: ..._ 4 2 0 TECHNICAL NOTES________________________________________________________ 6 3 0 PROGRAMMING FUNCTIONING___________________________________________ 7 4 0 SAFETY WARNINGS FOR MAINTENANCE AND USE___________________________ 10 WARRANTY__________________________________________________________________ 11 Guide for the causes research of some drawbacks_____________________ 11 GBR ...

Page 3: ...in series on SIC1 Ci riserviamo la proprietà di questo disegno con divieto di diffonderlo o riprodurlo senza nostra autorizzazione TRIMMER SEMPRE A POTENZA MASSIMA TRIMMER SEMPRE A POTENZA MASSIMA LAMPEGGIATORE V GBR CONTROL BOARD Antenna LED EXT COMMANDs INPUT ACCESSORIES TRAFFIC LIGHT ELECTRICAL VALVE POWER SUPPLY ENGINE Before the installation please read carefully this manual The company decli...

Page 4: ...mon 8 CONNECTION OF CONTROL BOARD OUTPUTS TERMINAL NOTES POWER SUPPLY OF AUXILIARY ACCESSORIES 13 24Vac MAX280mA 14 LED BRIGHT HEADS BOLLARDS is recommended to install a diode 13 24Vac 15 TRAFFIC LIGHT WITH TWO LIGHTS red green MAX 300W 16 GREEN LIGHT 17 RED LIGHT 18 COMMON neutral ELECTRIC VALVE 17 230Vac 160W ENGINE1 OPENING PHASE 22 230Vac MAX500W COMMON 23 CLOSING PHASE 24 500W MAX FOR ENGINE ...

Page 5: ...RONYM LED The LED diagnosis state has been realized at the first ignition of 1 column of the bollard totally lowered It lights when there is electrical network ON ON LED for control board programming It flashes for few seconds It is turned off during the functioning OK OFF It lights up when the button is pushed F1 6 OFF It flashes when the button clock is pushed F1A 7 OFF It turns off when the sto...

Page 6: ...SITIVE HEAD 24F 13 15 It has been projected to supply 1 flashing bright head 2 h INSTALLATION The control board must be installed in a protected and dry place with its own protection box Install a circuit breaker of type 0 03A high sensitivity to the supply of the control board Make sure the supply of the control board is 230Vac 10 50Hz For the control board electrical motor flashing light traffic...

Page 7: ...he code To match the radio command with STOP function activate the input STOP 3 open the contact while sending the code 3 d CANCELLATION SINGLE RADIO CODE PROCEDURE 1 Push twice the PROG button The LED OK is fixed ON while the LEDs EXT flash 2 Send the radio code to be cancelled 3 If the led OK flashes 3 times the code has been cancelled Instead if it flashes 1 time slowly it means that the radio ...

Page 8: ...me of traffic light is the available time for a vehicle to cross and free the passage since when the traffic light is red until the bollard starts its climb Meanwhile the leds incorporated in the head keep flashing see image A at page 8 point 5 In order to define the waiting time it is necessary to time how much a vehicles takes for crossing and freeing the passage see image A at page 8 PROCEDURE ...

Page 9: ...e clock the security F2 4 intervenes the bollard reopens and it will try to reclose after 5minutes The closing attempts will continue until the bollard isn t closed or coming a user s command 3 m ACTIVATION OF HYDRAULIC PRESSURE RETENTION To activate this function DIP 2 must be in ON When the system is in CLOSE state the control board check the position of closing limit switches If the limit switc...

Page 10: ...t the procedure 3 o RADIO REMOTE CONTROL PROGRAMMING 4 0 SAFETY WARNINGS FOR MAINTENANCE AND USE WARNINGS These warnings are integral and essential parts of the electronics and they are to be given to the final user So it is necessary to keep this manual Read carefully the instruction book which gives important indications about the installation The wrong installation or the improper use of the co...

Page 11: ...ation reversed limit switches lack of power supply control board damaged fuses damaged wrong connection of electrical engine wrong limit switch connection sectional swtich open control board damaged high absorption peak short circuit on the engine electrical valve inputs output24Vac traffic light rewire the electrical engine on the control board reverse rise fall wires rewire magnetic limit switch...

Page 12: ...m V R Com Com A C Stop blocco SIC1 Electrical valve 230V FC A M1 FC C WARNING The limit switches of the head must be connected in series on SIC1 Ci riserviamo la proprietà di questo disegno con divieto di diffonderlo o riprodurlo senza nostra autorizzazione TRIMMER SEMPRE A POTENZA MASSIMA TRIMMER SEMPRE A POTENZA MASSIMA LAMPEGGIATORE A C Com FC A M1 FC C LTL R SDL SIC 1 V GBR ...