WARNING
:
the grounding cable must be necessarily connected with the predisposed control board terminal: terminal
number 21.
eVeRY BoLLaRD HaS LaBeLLeD CaBLeS foR tHe eLeCtRICaL ConneCtIon WItH tHe
ContRoL BoaRD.
the current laws obligate this connection to avoid inopportune starting or missing stops in case of
breakdowns (both on input side and output side).
NOTES
mA (interruption)
FUSES
fUSeS foR tRaffIC LIGHt (engine absorbs 2500ma)
Traffic light MAX 500W(Relay maximum amperage of working 5A)
6300
f2
fUSeS foR aCCeS LeD
(Led absorbs 30ma, input boards 70ma)
315
f1
NOTES
ACRONYM
LED
The LED diagnosis state has been realized at the first ignition of 1 column of the bollard totally lowered.
It lights when there is electrical network
on
on
LED for control board programming
It flashes for few seconds
It is turned off during the functioning
oK
off
It lights up when the button is pushed
f1 (6)
off
It flashes when the button/clock is pushed
f1a (7)
off
It turns off when the stop button is pushed (stop button with self-
holding)
StoP (3)
on
It turns off with coil detection / sensitive head
f2 (4)
on
It turns off when the bollard is UP
fC (9)
on
It turns off when the bollard is DOWN
fa (10)
off
not USeD
SS
not USeD
SS2
DIP SWITCH
SIGLA
DEFAULT
3.l) CLoCK fUnCtIonInG (page 7)
Dip 1
off
3.m) PIStonS maIntenanCe (page 7)
Dip 2
off
3.n) eXCLUSIon LImIt SWItCH tIme (page 8)
Dip 4
off
Dip 3-5-6-7-8-9-10
Dip 3-5-6-7-8-9-10
off