DISASSEMBLY
Use pointed pliers to remove 2 ties that hold the Lid Lock
Harness, press and remove the ties without cutting them.
A plastic tie can be removed from under the Cover.
The other plastic tie can be removed from the top of the
Cover.
To remove the Magnet or Magnetic Switch, use a thin
flathead screwdriver.
Tub Cover
Manually release the snaps holding the Tub Cover to the
Tub.
Main Harness and Pressure Switch Hose - Tub
With tip pliers remove the ties that hold the Main Harness
and the Pressure Switch Hose to the Tub, press them and
remove them without cutting them.