13
|
Manual de Servicio
Ingenieria de Servicio
Pins
Value/ Comments
2 - 3
60 - 90 Ω
3 - 4
PTC OF CONTACT CLOSING WITH 127 VOLTAGE ACROSS TERMINALS 3-4
MUST SUPPLIED FOR 1.5 / 8 SEC DURING THIS INTERVAL THE
ELECTRICAL CONTACT BETWEEN TERMINAL 4-5 MUST BE CLOSED,
AFTER THE CONTACT 4-5 CLOSING AND A FOLLOWING PTC
ENERGIZATION OF 900 SEC THE UNLOCK TIME IN CASE OF ABSENCE THE
POWER MUST BE: 120 SEC MIN, ROOM TEMPERATURE 25°C MIN - 35°C
MAX. (THE UNLOCK TIME IS THE SLIDER MECHANICAL UNLOCK, WITH
THE SLIDER IN THE REST POSITION).
LID LOCK SWITCH
Valve
Voltage (V) Frequency (Hz)
Resistance (Ohms) (a 25°C)
Hot Water
110 / 120
50 / 60
1150 ± 5 %
Cold Water
110 / 120
50 / 60
1150 ± 5 %
Hot Water
220 / 240
50 / 60
3550 ± 10 %
Cold Water
220 / 240
50 / 60
3550 ± 10 %
WATER VALVES
Voltage (V)
110
220
Frequency (Hz)
60
50 / 60
Power (Steady State) (W)
5.8 +/- 1
5.5 +/- 1
Power (Peak) (W)
44
165
Current (Peak) (A)
0.5 - 1.5
0.5 - 1.5
Current (Steady State) (mA)
30 - 50
30 - 50
Resistance (Ohm)
1,779.4 - 2,520.8 7,446.1 - 10,755.5
Displacement Máx. (in)
TERMOACTUATOR
0.248 at 227 seconds
Pump Type
Voltage / Freq
Resistance (Ω)
(20°c)
Power (W)
Current (A)
Thermical Protector
(°C)
Dren
120V / 60Hz
10.9 ± 0.55
70 - 85
1.2 - 1.4
115 ± 5
Dren
220V / 60Hz
35.8 ± 1.8
70 - 85
0.07 - 0.8
135 ± 5
Dren
220V / 50Hz
128.6 ± 6.4
35 - 50
0.2 - 0.3
Impedance Protected
PUMP
TECHNICAL DATA
Summary of Contents for Centauro ICL2040 Series
Page 44: ...44 Manual de Servicio Ingenieria de Servicio Modelos El ctricos 127V DIAGRAMA EL CTRICO...
Page 45: ...45 Manual de Servicio Ingenieria de Servicio Modelos El ctricos 220V DIAGRAMA EL CTRICO...
Page 71: ...71 Manual de Servicio Ingenieria de Servicio GARANTIA...
Page 72: ...72 Manual de Servicio Ingenieria de Servicio...
Page 113: ...41 Manual de Servicio Ingenieria de Servicio CONTROL BOARD...
Page 115: ...43 Manual de Servicio Ingenieria de Servicio Electric Models 220V ELECTRIC DIAGRAM...