54
|
Manual de Servicio
Ingenieria de Servicio
ENTRY TO SERVICE MODE
Platform
Control Panel
Input method
Operation
Laundry
Centers
“Centaur
Standardization
”
CYCLES knob in OFF
position
LOAD LEVEL knob on
HIGH
During the first 10
seconds after
powering up the unit,
simultaneously press
SEL START
/ PAUSE for 2
seconds. The "SPIN"
led lights up
"SPIN" is test 1.
The test change is done
through the cycle knob.
Using the START / PAUSE
button it is possible to run or
stop the selected test.
Service mode is disabled after
5 minutes of inactivity
Description of Service Mode Tests
Test
Number
Test code
shown on
display
Service Mode Test
Laundry
Center
Test Description
1
t1
Cold water valve
(led "Spin")
X
Turn on valve during test (Auto-off in 60s)
2
t2
Hot water valve
(led "rinse")
X
Turn on valve during test (Auto-off in 60s)